Technische Produktdaten für FTXZ-N / RXZ-N

FTXZ25NV1B / RXZ25NV1B FTXZ35NV1B / RXZ35NV1B FTXZ50NV1B / RXZ50NV1B
Poff (AUS-Modus) W 1.0 1.0 1.0
Kühlung Psb (Standby-Modus Kühlung) W 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Saisonale Effizienz (gemäß EN14825) Kühlung Pdesign kW 2.50 3.50 5.00
    Jährlicher Energieverbrauch kWh 92 136 203
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 9.54 9.00 8.60
    Bedingung D (20°C – 27/19) Pdc kW 1.68 1.63 2.36
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.36 10.70 12.04
    Bedingung C (25°C – 27/19) Pdc kW 1.53 1.66 2.38
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 12.23 11.86 11.22
    Bedingung A (35 °C – 27/19) Pdc kW 2.50 3.50 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 6.18 5.27 4.36
    Bedingung B (30°C – 27/19) Pdc kW 1.84 2.58 3.71
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 8.92 7.66 6.69
  Heizen (durchschnittliches Klima) Jährlicher Energieverbrauch kWh 831 1,100 1,427
    Pdesign kW 3.50 4.50 5.60
    Erforderl. Reserve-Heizleistung bei Entwurfsbed. kW 0.66 0.91 1.02
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+++ A+++ A+++
    TBivalent Pdh (deklarierte Heizleistung) kW 3.10 3.98 4.95
      Tbiv (bivalente Temperatur) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 4.10 3.91 3.82
    Bedingung C (7 °C) Pdh (deklar. Heizleistung) kW 1.21 1.56 1.94
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 7.56 7.45 7.25
    TOL Tol (Temperaturbetriebsbereich) °C -15 -15 -15
      Pdh (deklarierte Heizleistung) kW 2.41 2.94 3.97
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 3.18 3.25 2.98
    Bedingung A (-7 °C) Pdh (deklar. Heizleistung) kW 3.10 3.98 4.95
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 4.10 3.91 3.82
    Bedingung D (12 °C) Pdh (deklar. Heizleistung) kW 0.79 0.69 0.91
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 8.30 8.09 6.33
    Bedingung B (2 °C) Pdh (deklar. Heizleistung) kW 1.88 2.42 3.02
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.81 5.57 5.42
Kühlleistung Nom. BTU/h 8,500 11,900 17,100
  Min. kW 0.6 0.6 0.6
  Nom. kcal/h 2,150 3,010 4,300
  Max. kW 3.9 5.3 5.8
  Min. kcal/h 520 520 520
  Min. BTU/h 2,000 2,000 2,000
  Nom. kW 2.5 3.5 5.0
  Max. BTU/h 13,100 18,100 19,400
  Max. kcal/h 3,350 4,560 4,990
Pck (Ölsumpfheizungsmodus) W 0.0 0.0 0.0
Nominale Effizienz Annual energy consumption kWh 205 (0.000) 330 (0.000) 550 (0.000)
  Richtlinie zur Energiekennzeichnung Heizen A A A
  Nominal efficiency-=-Cop 6.10 (1) 5.30 (1) 4.55 (1)
Heizen Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Rohrleitungsanschlüsse Liquid AD mm 6.35 6.35 6.35
  Gas AD mm 9.5 9.5 9.5
Heizleistung Min. BTU/h 2,000 2,000 2,000
  Nom. BTU/h 9,600 17,100 21,500
  Max. kcal/h 6,450 7,740 8,080
  Max. BTU/h 25,500 30,700 32,000
  Nom. kW 3.6 5.0 6.3
  Min. kW 0.6 0.6 0.6
  Nom. kcal/h 2,150 2,150 5,420
  Min. kcal/h 520 520 520
  Max. kW 7.5 9.0 9.4
Pto (Thermostat off) W 6.0 6.0 6.0
Leistungsaufnahme Kühlung Min. kW 0.11 0.11 0.11
    Nom. kW 0.41 0.66 1.10
    Max. kW 0.88 1.33 1.60
  Heizen Max. kW 2.01 2.53 2.64
    Min. kW 0.10 0.10 0.10
    Nom. kW 0.62 1.00 1.41
Kalte Saison inklusiv Ja Ja Ja
Strom Nennbetriebsstrom - 50 Hz Heizen A 2.9 (3), 2.8 (4), 2.7 (5) 4.6 (3), 4.4 (4), 4.3 (5) 6.5 (3), 6.2 (4), 6.0 (5)
    Kühlung A 2.0 (3), 1.9 (4), 1.9 (5) 3.1 (3), 2.9 (4), 2.8 (5) 5.1 (3), 4.9 (4), 4.6 (5)
Hinweise EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU
  Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast
  220 V 220 V 220 V
  230 V 230 V 230 V
  240 V 240 V 240 V