FTXS20K2V1B / RXS20L3V1B FTXS20K3V1B / RXS20L3V1B FTXS25K2V1B / RXS25L3V1B FTXS25K3V1B / RXS25L3V1B FTXS35K2V1B / RXS35L3V1B FTXS35K3V1B / RXS35L3V1B
Poff (AUS-Modus) W 1.0 1.0 1.0 1.0 1.0 1.0
Kühlung Psb (Standby-Modus Kühlung) W 1.0 1.0 1.0 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25 0.25 0.25 0.25
Feuchtigkeitsentzug Kühlung l/h           1.9
Saisonale Effizienz (gemäß EN14825) Kühlung Pdesign kW 2.00 2.00 2.50 2.50 3.50 3.50
    Jährlicher Energieverbrauch kWh 95 95 111 111 164 164
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 7.40 7.40 7.90 7.90 7.47 7.47
    Bedingung D (20°C – 27/19) Pdc kW 1.29 1.29 1.28 1.28 1.46 1.46
      Leistungsaufnahme kW 0.11 0.11 0.10 0.10 0.12 0.12
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.65 11.65 12.71 12.71 12.51 12.51
    Bedingung C (25°C – 27/19) Leistungsaufnahme kW 0.13 0.13 0.12 0.12 0.18 0.18
      Pdc kW 1.22 1.22 1.22 1.22 1.66 1.66
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 9.32 9.32 9.98 9.98 9.17 9.17
    Bedingung A (35 °C – 27/19) Leistungsaufnahme kW 0.46 0.46 0.59 0.59 0.90 0.90
      Pdc kW 2.00 2.00 2.50 2.50 3.50 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.39 4.39 4.21 4.21 3.89 3.89
    Bedingung B (30°C – 27/19) Pdc kW 1.47 1.47 1.84 1.84 2.58 2.58
      Leistungsaufnahme kW 0.21 0.21 0.27 0.27 0.42 0.42
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.99 6.99 6.71 6.71 6.10 6.10
  Heizen (durchschnittliches Klima) Jährlicher Energieverbrauch kWh 675 675 732 732 1,039 1,039
    Pdesign kW 2.30 2.30 2.50 2.50 3.60 3.60
    Erforderl. Reserve-Heizleistung bei Entwurfsbed. kW 0.11 0.11 0.15 0.15 0.55 0.55
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A++ A++ A++ A++ A++ A++
    TBivalent Pdh (deklarierte Heizleistung) kW 2.03 2.03 2.21 2.21 3.18 3.18
      Leistungsaufnahme kW 0.65 0.65 0.71 0.71 1.12 1.12
      Tbiv (bivalente Temperatur) °C -7 -7 -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.10 3.10 3.10 3.10 2.85 2.85
    Bedingung C (7 °C) Pdh (deklar. Heizleistung) kW 0.99 0.99 1.00 1.00 1.25 1.25
      Leistungsaufnahme kW 0.17 0.17 0.17 0.17 0.19 0.19
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.96 5.96 5.96 5.96 6.42 6.42
    TOL Tol (Temperaturbetriebsbereich) °C -15 -15 -15 -15 -15 -15
      Pdh (deklarierte Heizleistung) kW 2.47 2.47 2.59 2.59 2.84 2.84
      Leistungsaufnahme kW 0.98 0.98 1.04 1.04 1.22 1.22
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.52 2.52 2.50 2.50 2.33 2.33
    Bedingung A (-7 °C) Pdh (deklar. Heizleistung) kW 2.03 2.03 2.21 2.21 3.18 3.18
      Leistungsaufnahme kW 0.65 0.65 0.71 0.71 1.12 1.12
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.10 3.10 3.10 3.10 2.85 2.85
    Bedingung D (12 °C) Pdh (deklar. Heizleistung) kW 1.32 1.32 1.34 1.34 1.09 1.09
      Leistungsaufnahme kW 0.19 0.19 0.19 0.19 0.14 0.14
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.10 7.10 7.10 7.10 7.79 7.79
    Bedingung B (2 °C) Leistungsaufnahme kW 0.25 0.25 0.27 0.27 0.39 0.39
      Pdh (deklar. Heizleistung) kW 1.23 1.23 1.35 1.35 1.95 1.95
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.00 5.00 5.00 5.00 4.95 4.95
Kühlleistung Nom. BTU/h   6,800 (2)   8,500 (2)   11,900 (2)
  Min. kW           1.4
  Nom. kcal/h   1,720 (2)   2,150 (2)   3,010 (2)
  Max. kW           4.0
  Min. kcal/h   1,120   1,120   1,200
  Min. BTU/h   4,400   4,400   4,800
  Nom. kW 2.0 2.00 (2) 2.5 2.5 (2) 3.5 3.5 (2)
  Max. BTU/h   9,600   10,900   13,600
  Max. kcal/h   2,410   2,750   3,440
Pck (Ölsumpfheizungsmodus) W 0.0 0.0 0.0 0.0 0.0 0.0
Nominale Effizienz Jährlicher Energieverbrauch kWh 228 (0.000) 228 (0.000) 297 (0.000) 297 (0.000) 450 (0.000) 450 (0.000)
  Richtlinie zur Energiekennzeichnung Heizen A A A A A A
  Nominal efficiency-=-Cop 4.39 4.39 (1) 4.21 4.21 (1) 3.89 3.89 (1)
Heizen Heating-=-Heating cdh degradation heating 0.25 0.25 0.25 0.25 0.25 0.25
Rohrleitungsanschlüsse Liquid AD mm   6.35   6.35   6.35
  Gas AD mm   9.5   9.5   9.5
  Ableitung AD mm   18   18   18
Heizleistung Min. BTU/h   4,400   4,400   4,800
  Nom. BTU/h   8,500 (2)   9,600 (2)   13,600 (2)
  Max. kcal/h   3,700   4,040   4,470
  Max. BTU/h   14,700   16,000   17,700
  Nom. kW 2.5 2.5 (2) 2.8 2.8 (2) 4.0 4.00 (2)
  Min. kW   1.3   1.3   1.4
  Nom. kcal/h   2,150 (2)   2,410 (2)   3,440 (2)
  Min. kcal/h   1,120   1,120   1,200
  Max. kW   4.3   4.7   5.2
Pto (Thermostat off) W 20.0 20.0 21.0 21.0 28.0 28.0
Leistungsaufnahme Kühlung Min. kW   0.320   0.320   0.350
    Nom. kW 0.46 0.455 (2) 0.59 0.593 (2) 0.90 0.860 (2)
    Max. kW   0.760   1.000   1.190
  Heizen Max. kW   1.120   1.410   1.460
    Min. kW   0.310   0.310   0.340
    Nom. kW 0.53 0.530 (2) 0.60 0.600 (2) 0.84 0.840 (2)
Innengerät Ja Ja Ja Ja Ja Ja
Current Nennbetriebsstrom - 50 Hz Heizen A   2.80 (3), 2.70 (4), 2.60 (5)   3.30 (3), 3.20 (4), 3.10 (5)   4.30 (3), 4.10 (4), 3.90 (5)
    Kühlung A   2.54 (3), 2.43 (4), 2.33 (5)   3.33 (3), 3.23 (4), 3.12 (5)   4.60 (3), 4.39 (4), 4.18 (5)
Hinweise EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU
  Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast
Rohrleitungsanschlüsse Wärmeisolierung   Sowohl Flüssigkeits- als auch Gasleitungen   Sowohl Flüssigkeits- als auch Gasleitungen   Sowohl Flüssigkeits- als auch Gasleitungen
Hinweise   220 V   220 V   220 V
    230 V   230 V   230 V
    240 V   240 V   240 V