Technische Produktdaten für FTXK-AW / RXK-A

FTXK25AV1BW / RXK25AV1B FTXK35AV1BW / RXK35AV1B FTXK60AV1BW / RXK60AV1B FTXK50AV1BW / RXK50AV1B
Poff (AUS-Modus) W 12.7 7.8 10.4 17.3
Kühlung Psb (Standby-Modus Kühlung) W 12.7 7.8 10.4 17.3
Saisonale Effizienz (gemäß EN14825) Kühlung Pdesign kW 2.50 3.50 6.23 5.48
    Jährlicher Energieverbrauch kWh 155 209 359 324
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.66 5.86 6.09 5.93
    Bedingung D (20°C – 27/19) Pdc kW 1.15 1.20 2.41 2.48
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.32 10.30 10.23 11.95
    Bedingung C (25°C – 27/19) Pdc kW 1.22 1.60 2.94 2.59
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.92 7.12 7.76 8.02
    Bedingung A (35 °C – 27/19) Pdc kW 2.50 3.50 6.23 5.48
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.42 3.10 3.23 3.29
    Bedingung B (30°C – 27/19) Pdc kW 1.83 2.48 4.58 3.98
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.83 5.74 4.98 4.99
  Heizen (durchschnittliches Klima) Jährlicher Energieverbrauch kWh 792 945 1,310 1,177
    Pdesign kW 2.40 2.80 3.80 3.37
    Erforderl. Reserve-Heizleistung bei Entwurfsbed. kW 0.45 0.53 0.72 0.56
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+ A+ A+ A+
    TBivalent Pdh (deklarierte Heizleistung) kW 2.12 2.48 3.36 2.98
      Tbiv (bivalente Temperatur) °C -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.49 2.24 2.86 2.21
    Bedingung C (7 °C) Pdh (deklar. Heizleistung) kW 0.89 1.01 1.33 1.25
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.82 5.53 4.60 4.95
    TOL Tol (Temperaturbetriebsbereich) °C -14 -14 -14 -14
      Pdh (deklarierte Heizleistung) kW 1.72 1.99 2.71 2.57
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.31 2.12 2.47 2.04
    Bedingung A (-7 °C) Pdh (deklar. Heizleistung) kW 2.12 2.48 3.36 2.98
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.49 2.24 2.86 2.21
    Bedingung D (12 °C) Pdh (deklar. Heizleistung) kW 1.02 1.10 1.56 1.45
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.10 7.10 5.63 6.22
    Bedingung B (2 °C) Pdh (deklar. Heizleistung) kW 1.29 1.29 2.03 1.93
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.26 4.35 4.31 4.34
Kühlleistung Nom. BTU/h 8,500 (2) 11,900 (2) 21,300 (2) 18,700 (2)
  Min. kW 1.300 1.300 1.750 1.630
  Max. kW 3.000 3.800 6.500 6.200
  Min. BTU/h 4,400 4,400 6,000 5,600
  Nom. kW 2.500 (2) 3.500 (2) 6.230 (2) 5.480 (2)
  Max. BTU/h 10,200 13,000 22,200 21,200
Pck (Ölsumpfheizungsmodus) W 0.0 0.0 0.0 0.0
Nominale Effizienz Jährlicher Energieverbrauch kWh 365 (0.000) 537 (0.000) 964 (0.000) 851 (0.000)
  Richtlinie zur Energiekennzeichnung Heizen A A A A
  Nominal efficiency-=-Cop 3.42 (1) 3.26 (1) 3.23 (1) 3.22 (1)
Heizen Psb (Standby-Modus Heizen) W 12.7 7.8 10.4 17.3
Rohrleitungsanschlüsse Liquid AD mm 6.35 6.35 6.35 6.35
    Typ Überdruckventil Überdruckventil Überdruckventil Überdruckventil
  Gas AD mm 9.52 9.52 15.90 12.70
    Typ Überdruckventil Überdruckventil Überdruckventil Überdruckventil
Heizleistung Min. BTU/h 4,400 4,400 4,100 4
  Nom. BTU/h 11,300 (2) 12,300 (2) 21,800 (2) 19,200 (2)
  Max. BTU/h 13,600 16,200 27,300 22,500
  Nom. kW 3.300 (2) 3.600 (2) 6.400 (2) 5.620 (2)
  Min. kW 1.300 1.300 1.200 1.170
  Max. kW 4.000 4.750 8.000 6.600
Pto (Thermostat off) W 30.0 30.0 47.6 24.0
Leistungsaufnahme Kühlung Min. kW 0.280 0.290 0.280 0.290
    Nom. kW 0.731 (2) 1.075 (2) 1.931 (2) 1.700 (2)
    Max. kW 0.990 1.390 2.000 2.000
  Heizen Max. kW 1.100 1.480 2.000 2.510
    Min. kW 0.260 0.285 0.240 0.260
    Nom. kW 0.900 (2) 0.957 (2) 1.680 (2) 1.550 (2)
Innengerät Ja Ja Ja Ja
Current Nennbetriebsstrom - 50 Hz Heizen A 4.59 4.29 7.46 6.86
    Kühlung A 4.03 4.86 8.52 7.50
Hinweise EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU
  Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast
  Alle Geräte sind getestet und entsprechen ISO 5151 (Gerät ohne Kanal) oder ISO 13253 (Gerät mit Kanal). Alle Geräte sind getestet und entsprechen ISO 5151 (Gerät ohne Kanal) oder ISO 13253 (Gerät mit Kanal). Alle Geräte sind getestet und entsprechen ISO 5151 (Gerät ohne Kanal) oder ISO 13253 (Gerät mit Kanal). Alle Geräte sind getestet und entsprechen ISO 5151 (Gerät ohne Kanal) oder ISO 13253 (Gerät mit Kanal).
  Änderungen aller Technischen Daten durch den Hersteller ohne Ankündigung vorbehalten. Änderungen aller Technischen Daten durch den Hersteller ohne Ankündigung vorbehalten. Änderungen aller Technischen Daten durch den Hersteller ohne Ankündigung vorbehalten. Änderungen aller Technischen Daten durch den Hersteller ohne Ankündigung vorbehalten.