FTXA20A2V1BW / RXA20A2V1B FTXA20A2V1BW / RXA20A3V1B FTXA20A2V1BW / RXA20A5V1B FTXA25A2V1BW / RXA25A3V1B FTXA25A2V1BW / RXA25A5V1B FTXA35A2V1BW / RXA35A2V1B FTXA35A2V1BW / RXA35A3V1B FTXA35A2V1BW / RXA35A5V1B FTXA42A2V1BW / RXA42A2V1B FTXA50A2V1BW / RXA50A2V1B FTXA25A2V1BW / RXA25A2V1B (Archiviert)
Innengerät FTXA20A2V1BW   FTXA20A2V1BW   FTXA25A2V1BW FTXA35A2V1BW   FTXA35A2V1BW FTXA42A2V1BW FTXA50A2V1BW FTXA25A2V1BW
Außengerät RXA20A2V1B RXA20A2V1B RXA20A5V1B RXA25A2V1B RXA25A5V1B RXA35A2V1B RXA35A2V1B RXA35A5V1B RXA42A2V1B RXA50A2V1B RXA25A2V1B
Kühlleistung Min. kW 1.3 1.3 1.3 1.3 1.3 1.4 1.4 1.4 1.7 1.7 1.3
  Min. BTU/h 4,400.0 4,400.0 4,400.0 4,400.0 4,400.0 4,800.0 4,800.0 4,800.0 5,800.0 5,800.0 4,400.0
  Min. kcal/h 1,120.0 1,120.0 1,120.0 1,120.0 1,120.0 1,200.0 1,200.0 1,200.0 1,460.0 1,460.0 1,120.0
  Nom. kW 2.0 2.0 2.0 2.5 2.5 3.4 3.4 3.4 4.2 5.0 2.5
  Nom. BTU/h 6,800.0 6,800.0 6,800.0 8,500.0 8,500.0 11,600.0 11,600.0 11,600.0 14,300.0 17,100.0 8,500.0
  Nom. kcal/h 1,720.0 1,720.0 1,720.0 2,150.0 2,150.0 2,920.0 2,920.0 2,920.0 3,610.0 4,300.0 2,150.0
  Max. kW 2.6 2.6 2.6 3.2 3.2 4.0 4.0 4.0 5.0 5.3 3.2
  Max. BTU/h 8,900.0 8,900.0 8,900.0 10,900.0 10,900.0 13,600.0 13,600.0 13,600.0 17,100.0 18,100.0 10,900.0
  Max. kcal/h 2,240.0 2,240.0 2,240.0 2,750.0 2,750.0 3,440.0 3,440.0 3,440.0 4,300.0 4,560.0 2,750.0
Heizleistung Min. kW 1.30 1.30 1.30 1.30 1.30 1.40 1.40 1.40 1.70 1.70 1.30
  Min. BTU/h 4,400.0 4,400.0 4,400.0 4,400.0 4,400.0 4,800.0 4,800.0 4,800.0 5,800.0 5,800.0 4,400.0
  Min. kcal/h 1,120.0 1,120.0 1,120.0 1,120.0 1,120.0 1,200.0 1,200.0 1,200.0 1,460.0 1,460.0 1,120.0
  Nom. kW 2.50 2.50 2.50 2.80 2.80 4.00 4.00 4.00 5.40 5.80 2.80
  Nom. BTU/h 8,500.0 8,500.0 8,500.0 9,600.0 9,600.0 13,600.0 13,600.0 13,600.0 18,400.0 19,800.0 9,600.0
  Nom. kcal/h 2,150.0 2,150.0 2,150.0 2,410.0 2,410.0 3,440.0 3,440.0 3,440.0 4,640.0 4,990.0 2,410.0
  Max. kW 3.50 3.50 3.50 4.70 4.70 5.20 5.20 5.20 6.00 6.50 4.70
  Max. BTU/h 11,900.0 11,900.0 11,900.0 16,000.0 16,000.0 17,700.0 17,700.0 17,700.0 20,500.0 22,200.0 16,000.0
  Max. kcal/h 3,010.0 3,010.0 3,010.0 4,040.0 4,040.0 4,470.0 4,470.0 4,470.0 5,160.0 5,590.0 4,040.0
Leistungsaufnahme Kühlung Min. kW 0.27 0.27 0.27 0.27 0.27 0.31 0.31 0.31     0.27
    Nom. kW 0.43 0.43 0.43 0.56 0.56 0.78 0.78 0.78 1.05 1.36 0.56
    Max. kW 0.63 0.63 0.63 0.78 0.78 1.04 1.04 1.04     0.78
  Heizen Min. kW 0.25 0.25 0.25 0.25 0.25 0.26 0.26 0.26 0.46 0.49 0.25
    Nom. kW 0.50 0.50 0.50 0.56 0.56 0.99 0.99 0.99 1.31 1.45 0.56
    Max. kW 0.91 0.91 0.91 1.22 1.22 1.67 1.67 1.67     1.22
Nominale Effizienz EER   4.70 4.70 4.70 4.46 4.46 4.37 4.37 4.37 3.99 3.68 4.46
  COP   5.00 5.00 5.00 5.00 5.00 4.04 4.04 4.04 4.12 4.00 5.00
  Richtlinie zur Energiekennzeichnung Kühlen   A A A A A A A A A A A
    Heizen   A A A A A A A A A A A
Raumkühlen Leistung Pdesign kW 2.00 2.00 2.00 2.50 2.50 3.40 3.40 3.40 4.20 5.00 2.50
  Energieeffizienzklasse   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A+++
  SEER   8.75 8.75 8.75 8.74 8.74 8.73 8.73 8.73 7.50 7.33 8.74
  Jährlicher Energieverbrauch kWh/a 80 80 80 101 101 137 137 137 196 239 101
  Bedingung A (35 °C – 27/19) Pdc kW 2.00 2.00 2.00 2.50 2.50 3.40 3.40 3.40 4.20 5.00 2.50
    EERd   4.70 4.70 4.70 4.46 4.46 4.37 4.37 4.37 3.99 3.68 4.46
    Leistungsaufnahme kW 0.43 0.43 0.43 0.56 0.56 0.78 0.78 0.78 1.05 1.36 0.56
  Bedingung B (30 °C – 27/19) Pdc kW 1.47 1.47 1.47 1.84 1.84 2.51 2.51 2.51 3.09 3.68 1.84
    EERd   6.96 6.96 6.96 6.79 6.79 6.28 6.28 6.28 5.54 5.29 6.79
    Leistungsaufnahme kW 0.21 0.21 0.21 0.27 0.27 0.40 0.40 0.40 0.56 0.70 0.27
  Bedingung C (25 °C – 27/19) Pdc kW 0.95 0.95 0.95 1.18 1.18 1.61 1.61 1.61 1.99 2.37 1.18
    EERd   10.37 10.37 10.37 10.35 10.35 10.58 10.58 10.58 9.31 9.24 10.35
    Leistungsaufnahme kW 0.09 0.09 0.09 0.11 0.11 0.15 0.15 0.15 0.21 0.26 0.11
  Bedingung D (20 °C – 27/19) Pdc kW 1.27 1.27 1.27 1.29 1.29 1.33 1.33 1.33 1.86 1.87 1.29
    EERd   16.36 16.36 16.36 16.30 16.30 16.21 16.21 16.21 12.06 12.03 16.30
    Leistungsaufnahme kW 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.15 0.16 0.08
Raumheizen (Durchschnittliches Klima) Leistung Pdesign kW 2.40 2.40 2.40 2.45 2.45 2.50 2.50 2.50 3.80 4.00 2.45
  Energieeffizienzklasse   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A+++
  SCOP/A   5.15 5.15 5.15 5.15 5.15 5.15 5.15 5.15 4.60 4.60 5.15
  SCOPnet/A   5.19 5.19 5.19 5.18 5.18 5.18 5.18 5.18 4.63 4.61 5.18
  Pdh Heating capacity at -10° kW 2.19 2.19 2.19 2.30 2.30 2.36 2.36 2.36 3.34 3.45 2.30
  Jährlicher Energieverbrauch kWh/a 653 653 653 666 666 680 680 680 1,150 1,217 666
  Erforderliche Reserve-Heizleistung bei Auslegungsbedingungen kW 0.21 0.21 0.21 0.15 0.15 0.14 0.14 0.14 0.46 0.55 0.15
  TOL Tol (Temperaturbetriebsgrenze) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
    Pdh (deklarierte Heizleistung) kW 2.31 2.31 2.31 2.52 2.52 2.62 2.62 2.62 3.90 4.12 2.52
    COPd (deklarierter COP)   2.48 2.48 2.48 2.36 2.36 2.30 2.30 2.30 2.04 2.16 2.36
    Leistungsaufnahme kW 0.93 0.93 0.93 1.07 1.07 1.14 1.14 1.14 1.91 1.91 1.07
  TBivalent Tbiv (Bivalenz-Temperatur) °C -7 -7 -7 -7 -7 -7 -7 -7 -7 -7 -7
    Pdh (deklarierte Heizleistung) kW 2.12 2.12 2.12 2.17 2.17 2.21 2.21 2.21 3.36 3.54 2.17
    COPd (deklarierter COP)   3.56 3.56 3.56 3.59 3.59 3.58 3.58 3.58 3.24 3.16 3.59
    Leistungsaufnahme kW 0.60 0.60 0.60 0.60 0.60 0.62 0.62 0.62 1.04 1.12 0.60
  Bedingung A (-7 °C) Pdh (deklarierte Heizleistung) kW 2.12 2.12 2.12 2.17 2.17 2.21 2.21 2.21 3.36 3.54 2.17
    COPd (deklarierter COP)   3.56 3.56 3.56 3.59 3.59 3.58 3.58 3.58 3.24 3.16 3.59
    Leistungsaufnahme kW 0.60 0.60 0.60 0.60 0.60 0.62 0.62 0.62 1.04 1.12 0.60
  Bedingung B (2 °C) Pdh (deklarierte Heizleistung) kW 1.29 1.29 1.29 1.32 1.32 1.35 1.35 1.35 2.05 2.15 1.32
    COPd (deklarierter COP)   5.24 5.24 5.24 5.22 5.22 5.19 5.19 5.19 4.44 4.43 5.22
    Leistungsaufnahme kW 0.25 0.25 0.25 0.25 0.25 0.26 0.26 0.26 0.46 0.49 0.25
  Bedingung C (7 °C) Pdh (deklarierte Heizleistung) kW 0.92 0.92 0.92 0.94 0.94 0.94 0.94 0.94 1.65 1.71 0.94
    COPd (deklarierter COP)   6.27 6.27 6.27 6.25 6.25 6.19 6.19 6.19 6.33 6.32 6.25
    Leistungsaufnahme kW 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.26 0.27 0.15
  Bedingung D (12 °C) Pdh (deklarierte Heizleistung) kW 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.52 1.52 1.10
    COPd (deklarierter COP)   8.05 8.05 8.05 8.02 8.02 7.97 7.97 7.97 7.35 7.25 8.02
    Leistungsaufnahme kW 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.21 0.21 0.14
Raumheizen (Warmes Klima) Leistung Pdesign kW 1.75 1.75 1.75 1.87 1.87 2.00 2.00 2.00 2.15 2.15 1.87
  Energieeffizienzklasse   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
  SCOP   6.26 6.26 6.26 6.26 6.26 6.28 6.28 6.28 5.93 5.84 6.26
  SCOPnet   6.42 6.42 6.42 6.42 6.42 6.42 6.42 6.42 6.03 5.95 6.42
  Jährlicher Energieverbrauch kWh/a 392 392 392 418 418 446 446 446 508 515 418
  Erforderliche Reserve-Heizleistung bei Auslegungsbedingungen kW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  TOL Tol (Temperaturbetriebsgrenze) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
    Pdh (deklarierte Heizleistung) kW 2.31 2.31 2.31 2.52 2.52 2.62 2.62 2.62 3.90 4.12 2.52
    COPd (deklarierter COP)   2.48 2.48 2.48 2.36 2.36 2.30 2.30 2.30 2.04 2.16 2.36
    Leistungsaufnahme kW 0.93 0.93 0.93 1.07 1.07 1.14 1.14 1.14 1.91 1.91 1.07
  TBivalent Tbiv (Bivalenz-Temperatur) °C 2 2 2 2 2 2 2 2 2 2 2
    Pdh (deklarierte Heizleistung) kW 1.75 1.75 1.75 1.87 1.87 2.00 2.00 2.00 2.15 2.15 1.87
    COPd (deklarierter COP)   4.76 4.76 4.76 4.67 4.67 4.64 4.64 4.64 4.42 4.43 4.67
    Leistungsaufnahme kW 0.37 0.37 0.37 0.40 0.40 0.43 0.43 0.43 0.49 0.49 0.40
  Bedingung B (2 °C) Pdh (deklarierte Heizleistung) kW 1.75 1.75 1.75 1.87 1.87 2.00 2.00 2.00 2.15 2.15 1.87
    COPd (deklarierter COP)   4.76 4.76 4.76 4.67 4.67 4.64 4.64 4.64 4.42 4.43 4.67
    Leistungsaufnahme kW 0.37 0.37 0.37 0.40 0.40 0.43 0.43 0.43 0.49 0.49 0.40
  Bedingung C (7 °C) Pdh (deklarierte Heizleistung) kW 1.16 1.16 1.16 1.20 1.20 1.29 1.29 1.29 1.71 1.71 1.20
    COPd (deklarierter COP)   6.15 6.15 6.15 6.12 6.12 6.11 6.11 6.11 6.43 6.32 6.12
    Leistungsaufnahme kW 0.19 0.19 0.19 0.20 0.20 0.21 0.21 0.21 0.27 0.27 0.20
  Bedingung D (12 °C) Pdh (deklarierte Heizleistung) kW 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.5 1.5 1.1
    COPd (deklarierter COP)   8.05 8.05 8.05 8.02 8.02 7.97 7.97 7.97 7.35 7.25 8.02
    Leistungsaufnahme kW 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.21 0.21 0.14
Energieverbrauch in Betriebsarten „Nicht aktiv“ Crankcase heater mode PCK W 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
  Modus AUS POFF W 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
  Standby-Modus Kühlen PSB W 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
    Heizen PSB W 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
  Modus „Thermostat AUS“ PTO Kühlen W 7 7 7 7 7 7 7 7 13 13 7
      Heizen W 13 13 13 13 13 13 13 13 13 13 13
Kühlung Cdc (Absinken Kühlung)   0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Heizen Cdh (Absinken Heizen)   0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Kühlfunktion inklusiv Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
Heizfunktion inklusiv Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
Durchschnittliches Klima inklusiv Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
Kalte Saison inklusiv Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein
Warme Saison inklusiv Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
Eco-Labellogo Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein
Eurovent Sound power level outdoor Cooling Nom. dB(A) 59 59 59 59 59 61 61 61 62 62 59
  Schallleistungspegel innen Kühlung Nom. dB(A) 57 57 57 57 57 60 60 60 60 60 57
  Leitungslänge Kühlung Messbedingung m 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0
Leistungsfaktor Nennwert Kühlen % 91.73 (0.000) 91.73 (0.000) 91.73 (0.000) 93.94 (0.000) 93.94 (0.000) 95.64 (0.000) 95.64 (0.000) 95.64 (0.000) 94.10 (0.000) 95.74 (0.000) 93.94 (0.000)
    Heizen % 93.11 (0.000) 93.11 (0.000) 93.11 (0.000) 93.94 (0.000) 93.94 (0.000) 98.09 (0.000) 98.09 (0.000) 98.09 (0.000) 95.47 (0.000) 96.21 (0.000) 93.94 (0.000)
Current Nennbetriebsstrom - 50 Hz Kühlung A 2.0 2.0 2.0 2.6 2.6 3.6 3.6 3.6 4.9 6.2 2.6
    Heizen A 2.3 2.3 2.3 2.6 2.6 4.4 4.4 4.4 6.0 6.6 2.6