Technische Produktdaten für FTX-J3 / RX-K

FTX20J3V1B / RX20K5V1B FTX20J3V1B / RX20K2V1B FTX25J3V1B / RX25K5V1B FTX25J3V1B / RX25K2V1B FTX35J3V1B / RX35K5V1B FTX35J3V1B / RX35K2V1B
Poff (AUS-Modus) W 1.0 1.0 1.0 1.0 1.0 1.0
Kühlung Psb (Standby-Modus Kühlung) W 1.0 1.0 1.0 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25 0.25 0.25 0.25
Saisonale Effizienz (gemäß EN14825) Kühlung Pdesign kW 2.00 2.00 2.50 2.50 3.30 3.30
    Jährlicher Energieverbrauch kWh 115 115 143 142 188 188
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.11 6.11 6.15 6.15 6.15 6.15
    Bedingung D (20°C – 27/19) Pdc kW 1.15 1.15 1.15 1.15 1.20 1.20
      Leistungsaufnahme kW 0.13 0.12 0.13 0.13 0.13 0.12
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.46 9.46 9.20 9.20 9.91 9.91
    Bedingung C (25°C – 27/19) Leistungsaufnahme kW 0.17 0.16 0.16 0.16 0.23 0.23
      Pdc kW 1.22 1.22 1.22 1.22 1.60 1.60
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.55 7.55 7.80 7.80 6.98 6.98
    Bedingung A (35 °C – 27/19) Leistungsaufnahme kW 0.49 0.49 0.71 0.70 1.03 1.03
      Pdc kW 2.00 2.00 2.50 2.50 3.30 3.30
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.09 4.09 3.55 3.55 3.21 3.21
    Bedingung B (30°C – 27/19) Pdc kW 1.56 1.56 1.84 1.84 2.43 2.43
      Leistungsaufnahme kW 0.27 0.27 0.35 0.35 0.44 0.44
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.83 5.83 5.27 5.27 5.55 5.55
  Heizen (durchschnittliches Klima) Jährlicher Energieverbrauch kWh 710 711 808 809 947 947
    Pdesign kW 2.20 2.20 2.40 2.40 2.80 2.80
    Erforderl. Reserve-Heizleistung bei Entwurfsbed. kW 0.38 0.39 0.42 0.43 0.50 0.50
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+ A+ A+ A+ A+ A+
    TBivalent Pdh (deklarierte Heizleistung) kW 1.95 1.95 2.13 2.13 2.48 2.48
      Leistungsaufnahme kW 0.71 0.71 0.86 0.85 1.11 1.11
      Tbiv (bivalente Temperatur) °C -7 -7 -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.76 2.76 2.50 2.50 2.24 2.24
    Bedingung C (7 °C) Pdh (deklar. Heizleistung) kW 0.90 0.90 0.89 0.89 1.00 1.00
      Leistungsaufnahme kW 0.16 0.16 0.16 0.16 0.18 0.18
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.70 5.70 5.61 5.61 5.60 5.60
    TOL Tol (Temperaturbetriebsbereich) °C -15 -15 -15 -15 -15 -15
      Pdh (deklarierte Heizleistung) kW 1.59 1.59 1.72 1.72 1.99 1.99
      Leistungsaufnahme kW 0.65 0.65 0.75 0.74 0.94 0.94
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.46 2.46 2.31 2.31 2.12 2.12
    Bedingung A (-7 °C) Pdh (deklar. Heizleistung) kW 1.95 1.95 2.13 2.13 2.48 2.48
      Leistungsaufnahme kW 0.71 0.71 0.86 0.85 1.11 1.11
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.76 2.76 2.50 2.50 2.24 2.24
    Bedingung D (12 °C) Pdh (deklar. Heizleistung) kW 1.02 1.02 1.02 1.02 1.10 1.10
      Leistungsaufnahme kW 0.15 0.15 0.16 0.15 0.17 0.16
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.85 6.85 6.74 6.74 6.86 6.86
    Bedingung B (2 °C) Leistungsaufnahme kW 0.27 0.27 0.31 0.31 0.36 0.35
      Pdh (deklar. Heizleistung) kW 1.18 1.18 1.29 1.29 1.51 1.51
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.45 4.45 4.19 4.19 4.31 4.31
Kühlleistung Nom. BTU/h 6,800 (2) 6,800 (2) 8,500 (2) 8,500 (2) 11,300 (2) 11,300 (2)
  Min. kW 1.3 1.3 1.3 1.3 1.3 1.3
  Nom. kcal/h 1,720 (2) 1,720 (2) 2,150 (2) 2,150 (2) 2,840 (2) 2,840 (2)
  Max. kW 2.6 2.6 3.0 3.0 3.8 3.8
  Min. kcal/h 1,120 1,120 1,120 1,120 1,120 1,120
  Min. BTU/h 4,400 4,400 4,400 4,400 4,400 4,400
  Nom. kW 2.0 (2) 2.0 (2) 2.5 (2) 2.5 (2) 3.3 (2) 3.3 (2)
  Max. BTU/h 8,900 8,900 10,200 10,200 13,000 13,000
  Max. kcal/h 2,240 2,240 2,580 2,580 3,270 3,270
Pck (Ölsumpfheizungsmodus) W 0.0 0.0 0.0 0.0 0.0 0.0
Nominale Effizienz Annual energy consumption kWh 244 (0.000) 244 (0.000) 352 (0.000) 352 (0.000) 514 (0.000) 514 (0.000)
  Richtlinie zur Energiekennzeichnung Heizen A A A A A A
  Nominal efficiency-=-Cop 4.09 (1) 4.09 (1) 3.55 (1) 3.55 (1) 3.21 (1) 3.21 (1)
Heizen Psb (Standby-Modus Heizen) W 1.0   1.0   1.0  
  Heating-=-Heating cdh degradation heating 0.25 0.25 0.25 0.25 0.25 0.25
Rohrleitungsanschlüsse Liquid AD mm 6.35 6.35 6.35 6.35 6.35 6.35
  Gas AD mm 9.5 9.5 9.5 9.5 9.5 9.5
  Ableitung AD mm 18 18 18 18 18 18
  Wärmeisolierung Sowohl Flüssigkeits- als auch Gasleitungen Sowohl Flüssigkeits- als auch Gasleitungen Sowohl Flüssigkeits- als auch Gasleitungen Sowohl Flüssigkeits- als auch Gasleitungen Sowohl Flüssigkeits- als auch Gasleitungen Sowohl Flüssigkeits- als auch Gasleitungen
Heizleistung Min. BTU/h 4,400 4,400 4,400 4,400 4,400 4,400
  Nom. BTU/h 8,500 (2) 8,500 (2) 9,600 (2) 9,600 (2) 11,900 (2) 11,900 (2)
  Max. kcal/h 3,010 3,010 3,440 3,440 4,130 4,130
  Max. BTU/h 11,900 11,900 13,600 13,600 16,400 16,400
  Nom. kW 2.5 (2) 2.5 (2) 2.8 (2) 2.8 (2) 3.5 (2) 3.5 (2)
  Min. kW 1.3 1.3 1.3 1.3 1.3 1.3
  Nom. kcal/h 2,150 (2) 2,150 (2) 2,410 (2) 2,410 (2) 3,010 (2) 3,010 (2)
  Min. kcal/h 1,120 1,120 1,120.0 1,120.0 1,120 1,120
  Max. kW 3.5 3.5 4.0 4.0 4.8 4.8
Pto (Thermostat off) W 30.0 30.0 30.0 30.0 30.0 30.0
Leistungsaufnahme Kühlung Min. kW 0.310 0.310 0.310 0.310 0.290 0.290
    Nom. kW 0.490 (2) 0.490 (2) 0.700 (2) 0.700 (2) 1.030 (2) 1.030 (2)
    Max. kW 0.720 0.720 1.050 1.050 1.300 1.300
  Heizen Max. kW 0.950 0.950 1.110 1.110 1.290 1.290
    Min. kW 0.250 0.250 0.250 0.250 0.290 0.290
    Nom. kW 0.590 (2) 0.590 (2) 0.690 (2) 0.690 (2) 0.930 (2) 0.930 (2)
Innengerät Ja Ja Ja Ja Ja Ja
Strom Nennbetriebsstrom - 50 Hz Heizen A 3.0 3.0 3.2 3.2 4.7 4.7
    Kühlung A 2.4 2.4 3.6 3.6 5.5 5.5
Hinweise EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU
  Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast