FFQ25C2VEB / RXL25K3V1B FFQ35C2VEB / RXL35K2V1B FFQ50C2VEB / RXL50K2V1B
Poff (AUS-Modus) W 15.0 14.0 15.0
Kühlung Psb (Standby-Modus Kühlung) W 20.0 14.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Saisonale Effizienz (gemäß EN14825) Kühlung Pdesign kW 2.50 3.40 5.00
    Jährlicher Energieverbrauch kWh 167 210 307
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.25 5.66 5.70
    Bedingung D (20°C – 27/19) Pdc kW 2.17 1.87 2.32
      Leistungsaufnahme kW 0.22 0.18 0.22
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.96 10.61 10.41
    Bedingung C (25°C – 27/19) Leistungsaufnahme kW 0.25 0.21 0.31
      Pdc kW 2.03 1.78 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.02 8.39 7.72
    Bedingung A (35 °C – 27/19) Leistungsaufnahme kW 0.56 0.93 1.57
      Pdc kW 2.50 3.40 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.45 3.66 3.18
    Bedingung B (30°C – 27/19) Pdc kW 1.95 2.51 3.68
      Leistungsaufnahme kW 0.29 0.42 0.71
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.68 5.99 5.20
  Heizen (durchschnittliches Klima) Jährlicher Energieverbrauch kWh 807 1,209 1,331
    Pdesign kW 2.31 3.45 3.84
    Erforderl. Reserve-Heizleistung bei Entwurfsbed. kW 0.28 0.62 0.33
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+ A A
    TBivalent Pdh (deklarierte Heizleistung) kW 2.03 3.05 3.40
      Leistungsaufnahme kW 1.46 1.02 1.47
      Tbiv (bivalente Temperatur) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 1.39 2.98 2.32
    Bedingung C (7 °C) Pdh (deklar. Heizleistung) kW 1.11 1.48 1.40
      Leistungsaufnahme kW 0.21 0.28 0.25
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.25 5.34 5.50
    TOL Tol (Temperaturbetriebsbereich) °C -15 -25 -25
      Pdh (deklarierte Heizleistung) kW 2.02 1.71 4.06
      Leistungsaufnahme kW 1.07 1.69 2.74
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.88 1.01 1.48
    Bedingung A (-7 °C) Pdh (deklar. Heizleistung) kW 2.03 3.06 3.41
      Leistungsaufnahme kW 1.46 1.02 1.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 1.39 2.99 2.31
    Bedingung D (12 °C) Pdh (deklar. Heizleistung) kW 1.30 1.70 1.64
      Leistungsaufnahme kW 0.20 0.27 0.23
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.42 6.38 6.99
    Bedingung B (2 °C) Leistungsaufnahme kW 0.28 0.48 0.51
      Pdh (deklar. Heizleistung) kW 1.24 1.86 2.08
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.37 3.84 4.06
Kühlleistung Nom. BTU/h   11,590 17,050
  Min. kW   1.4 1.4
  Nom. kcal/h   2,920 4,300
  Max. kW   4.0 5.3
  Min. kcal/h   1,200 1,200
  Min. BTU/h   4,770 4,770
  Nom. kW 2.50 3.40 5.00
  Max. BTU/h   13,640 18,070
  Max. kcal/h   3,440 4,560
Pck (Ölsumpfheizungsmodus) W 0.0 0.0 0.0
Nominale Effizienz Jährlicher Energieverbrauch kWh 280 (0.000) 460 (0.000) 780 (0.000)
  Richtlinie zur Energiekennzeichnung Heizen A A A
  Nominal efficiency-=-Cop 4.46 3.70 3.21
Heizen Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Heizleistung Min. BTU/h   4,430 4,770
  Nom. BTU/h   14,320 19,780
  Max. kcal/h   4,380 5,330
  Max. BTU/h   17,390 21,140
  Nom. kW 3.20 4.20 5.80
  Min. kW   1.3 1.4
  Nom. kcal/h   3,610 4,990
  Min. kcal/h   1,120 1,200
  Max. kW   5.1 6.2
Pto (Thermostat off) W 40.0 40.0 40.0
Leistungsaufnahme Kühlung Min. kW   0.360 0.540
    Nom. kW 0.56 0.920 1.560
    Max. kW   1.470 2.030
  Heizen Max. kW   1.650 2.170
    Min. kW   0.300 0.250
    Nom. kW 0.84 1.230 1.660
Kalte Saison inklusiv Ja Ja Ja
Hinweise EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU
  Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast