FDXS50F2VEB9 / RXS50L2V1B
Poff (AUS-Modus) W 15.0
Kühlung Psb (Standby-Modus Kühlung) W 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Saisonale Effizienz (gemäß EN14825) Kühlung Pdesign kW 5.00
    Jährlicher Energieverbrauch kWh 306
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.72
    Bedingung D (20°C – 27/19) Pdc kW 2.26
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.38
    Bedingung C (25°C – 27/19) Pdc kW 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.41
    Bedingung A (35 °C – 27/19) Pdc kW 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.41
    Bedingung B (30°C – 27/19) Pdc kW 3.67
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.91
  Heizen (durchschnittliches Klima) Jährlicher Energieverbrauch kWh 1,425
    Pdesign kW 4.00
    Erforderl. Reserve-Heizleistung bei Entwurfsbed. kW 0.45
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A
    TBivalent Pdh (deklarierte Heizleistung) kW 3.54
      Tbiv (bivalente Temperatur) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.43
    Bedingung C (7 °C) Pdh (deklar. Heizleistung) kW 1.62
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.92
    TOL Tol (Temperaturbetriebsbereich) °C -15
      Pdh (deklarierte Heizleistung) kW 3.59
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.88
    Bedingung A (-7 °C) Pdh (deklar. Heizleistung) kW 3.54
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.43
    Bedingung D (12 °C) Pdh (deklar. Heizleistung) kW 1.92
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.15
    Bedingung B (2 °C) Pdh (deklar. Heizleistung) kW 2.15
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.11
Kühlleistung Nom. BTU/h 17,100
  Min. kW 1.7
  Nom. kcal/h 4,300
  Max. kW 5.3
  Min. kcal/h 1,460
  Min. BTU/h 5,800
  Nom. kW 5.0
  Max. BTU/h 18,100
  Max. kcal/h 4,560
Pck (Ölsumpfheizungsmodus) W 0.0
Nominale Effizienz Jährlicher Energieverbrauch kWh 825 (0.000)
  Richtlinie zur Energiekennzeichnung Heizen B
  Nominal efficiency-=-Cop 3.03
Heizen Heating-=-Heating cdh degradation heating 0.25
Rohrleitungsanschlüsse Liquid AD mm 6.35
  Gas AD mm 12.7
  Ableitung AD mm VP20 (Außendurchmesser 26, Innendurchmesser 20)
  Wärmeisolierung Sowohl Flüssigkeits- als auch Gasleitungen
Heizleistung Min. BTU/h 5,800
  Nom. BTU/h 19,800
  Max. kcal/h 5,160
  Max. BTU/h 20,500
  Nom. kW 5.8
  Min. kW 1.7
  Nom. kcal/h 4,990
  Min. kcal/h 1,460
  Max. kW 6.0
Pto (Thermostat off) W 9.0
Leistungsaufnahme Kühlung Nom. kW 1.650
  Heizen Nom. kW 1.870
Kalte Saison inklusiv Ja
Current Nennbetriebsstrom - 50 Hz Heizen A 8.3 (2)
    Kühlung A 7.1 (2)
Hinweise EER/COP gemäß Eurovent 2012, nur zur Verwendung außerhalb der EU
  230 V
  Nominale Effizienz: Kühlen bei 35 °C/27 °C Nennlast, Heizen bei 7 °C/20 °C Nennlast