EHVH04S18CB3V / ERLQ004CAV3 EHVH08S26CB9W / ERLQ006CAV3 EHVH08S18CB3V / ERLQ006CAV3 EHVH08S26CB9W / ERLQ008CAV3 EHVH08S18CB3V / ERLQ008CAV3 EHVH11S18CB3V / ERLQ011CAV3 EHVH11S26CB9W / ERLQ011CAV3 EHVH16S26CB9W / ERLQ014CAV3 EHVH16S18CB3V / ERLQ014CAV3 EHVH16S18CB3V / ERLQ016CAV3 EHVH16S26CB9W / ERLQ016CAV3
Trinkwassererwärmung Allgemein Deklariertes Lastprofil Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
  Kaltes Klima AEC (Jährlicher Stromverbrauch) kWh 1,221 2,037 1,332 2,037 1,332 1,340 1,980 1,980 1,340 1,340 1,980
    Qelec (Täglicher Stromverbrauch) kWh 5.55 9.26 6.05 9.26 6.05 6.08 8.99 8.99 6.08 6.08 8.99
    Ƞwh (Wasserheizeffizienz) % 84.0 83.0 77.5 83.0 77.5 76.6 85.1 85.1 76.6 76.6 85.1
    AFC (Jährlicher Brennstoffverbrauch) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Qfuel (Täglicher Brennstoffverbrauch) kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Warmes Klima Qelec (Täglicher Stromverbrauch) kWh 4.39 8.11 5.10 8.11 5.10 5.04 7.40 7.40 5.04 5.04 7.40
    AEC (Jährlicher Stromverbrauch) kWh 966 1,784 1,123 1,784 1,123 1,110 1,630 1,630 1,110 1,110 1,630
    Qfuel (Täglicher Brennstoffverbrauch) kWh           0.00 0.00 0.00 0.00 0.00 0.00
    AFC (Jährlicher Brennstoffverbrauch) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Ƞwh (Wasserheizeffizienz) % 106 94.0 91.8 94.0 91.8 92.3 103 103 92.3 92.3 103
  Durchschnittliches Klima Ƞwh (Wasserheizeffizienz) % 95.0 90.0 86.4 90.0 86.4 87.4 97.7 97.7 87.4 87.4 97.7
    AFC (Jährlicher Brennstoffverbrauch) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Qelec (Täglicher Stromverbrauch) kWh 4.93 8.50 5.43 8.50 5.43 5.32 7.83 7.83 5.32 5.32 7.83
    Qfuel (Täglicher Brennstoffverbrauch) kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    AEC (Jährlicher Stromverbrauch) kWh 1,084 1,871 1,194 1,871 1,194 1,170 1,720 1,720 1,170 1,170 1,720
    Energieeffizienzklasse Wasserheizung A A A A A A A A A A A
Raumheizen allgemein Sole/Wasser-zu-Wasser-Gerät Nenndurchfluss Wasser/Sole m³/h     0.00 0.00 0.00            
  Luft-zu-Wasser-Gerät Nenn-Luftstrom (außen) m³/h 2,700 2,820 2,820 2,820 2,820 5,400 5,400 5,400 5,400 5,400 5,400
  Sonstiges Psb (Standby-Modus) kW 0.0080 0.0080 0.0080 0.0080 0.0080 0.055 0.055 0.055 0.055 0.055 0.055
    Poff (Modus AUS) kW 0.0080 0.0080 0.0080 0.0080 0.0080 0.055 0.055 0.055 0.055 0.055 0.055
    Pto (Thermostat AUS) kW 0.0060 0.0070 0.0070 0.0080 0.0080 0.057 0.057 0.057 0.057 0.057 0.057
    Pck (Kurbelwannenheizbetrieb) kW 0.00 0.00 0.00 0.00 0.00 0.055 0.055 0.055 0.055 0.055 0.055
    Leistungsregelung 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
  Integrierter Zusatzheizer Psup kW 3.00 3.00 3.00 9.00 3.00 3.00 9.00 9.00 3.00 3.00 9.00
    NOx-Emission mg/kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Art der Energieaufnahme Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch
Wasserseitiger Wärmetauscher Wasserdurchfluss Heizen Nom. l/min 12.6 (5), 11.6 (6) 17.2 (5), 16.3 (6) 17.2 (5), 16.3 (6) 21.2 (5), 19.8 (6) 21.2 (5), 19.8 (6) 32.1 (7), 31.5 (8) 32.1 (7), 31.5 (8) 41.6 (7), 39.0 (8) 41.6 (7), 39.0 (8) 45.9 (7), 43.6 (8) 45.9 (7), 43.6 (8)
Pumpe Gerät mit nominalem externen statischen Druck Heizen kPa 53.0 (5), 56.0 (6) 45.0 (5), 47.0 (6) 45.0 (5), 47.0 (6) 33.0 (5), 37.0 (6) 33.0 (5), 37.0 (6) 34.2 (7), 35.9 (8) 34.2 (7), 35.9 (8) 43.2 (7), 51.2 (8) 43.2 (7), 51.2 (8) 26.8 (7), 36.3 (8) 26.8 (7), 36.3 (8)
Raumheizen Wasserauslass kaltes Klima 55 °C Allgemein Prated bei -22°C kW 2.39 2.60 2.60 3.56 3.56 6.99 6.99 8.15 8.15 9.12 9.12
      Jährlicher Energieverbrauch kWh 2,133 2,306 2,306 3,088 3,088 6,740 6,740 7,870 7,870 8,580 8,580
      Saisonale Effizienz Raumheizen % 107 107 107 110 110 95.0 95.0 95.5 95.5 98.3 98.3
      Jährlicher Energieverbrauch (GCV) Gj 7.68 8.30 8.30 11.1 11.1 24.3 24.3 28.3 28.3 30.9 30.9
  Wasserauslass 35°C für durchschnittliches Klima Bedingung A (-7 °C TK/-8 °C FK) PERd % 120 108 108 108 108 105 105 105 105 93.2 93.2
      Pdh kW 4.01 4.72 4.72 6.68 6.68 8.88 8.88 10.7 10.7 12.4 12.4
      Space heating-=-Average climate water outlet 35°C-=-A Condition (-7°CDB/-8°CWB)-=-Copd 3.01 2.69 2.69 2.69 2.69 2.63 2.63 2.63 2.63 2.33 2.33
    Bedingung C (7 °C TK/6 °C FK) Pdh kW 1.70 2.59 2.59 2.59 2.59 5.74 5.74 5.05 5.05 5.74 5.74
      PERd % 234 230 230 230 230 271 271 228 228 271 271
      Space heating-=-Average climate water outlet 35°C-=-C Condition (7°CDB/6°CWB)-=-Copd 0.980 0.980 0.980 1.00 1.00 0.940 0.940 1.00 1.00 0.940 0.940
    Bedingung D (12 °C TK/11 °C FK) Pdh kW 39.2 2.61 2.61 2.61 2.61 6.50 6.50 5.16 5.16 6.50 6.50
      PERd % 308 291 291 291 291 359 359 268 268 359 359
      Space heating-=-Average climate water outlet 35°C-=-D Condition (12°CDB/11°CWB)-=-Copd 0.980 0.980 0.980 0.980 0.980 0.920 0.920 0.930 0.930 0.920 0.920
    Bedingung G (-15 °C TK/–) PERd % 0.00 0.00 0.00 0.00 0.00            
      Pdh kW 0.00 0.00 0.00 0.00 0.00            
      Space heating-=-Average climate water outlet 35°C-=-G Condition (-15°CDB/-)-=-Copd 0.00 0.00 0.00 0.00 0.00            
    Nennleistung Wärmeabgabe Zusatzheizer Psup (bei Tdesign -10 °C) kW 0.040 0.640 0.640 0.590 0.590 2.44 2.44 1.93 1.93 4.35 4.35
    Allgemein Jährlicher Energieverbrauch kWh 1,980 2,540 2,540 3,489 3,489 5,380 5,380 7,250 7,250 8,270 8,270
      Jährlicher Energieverbrauch (GCV) Gj 7.13 9.14 9.14 12.6 12.6 19.4 19.4 26.1 26.1 29.8 29.8
      Ƞs (Saisonale Effizienz Raumheizen) % 178 169 169 171 171 156 156 153 153 149 149
      Prated bei -10 °C kW 4.40 5.34 5.34 7.40 7.40 11.2 11.2 14.5 14.5 16.0 16.0
      Space heating-=-Average climate water outlet 35°C-=-General-=-Seasonal space heating eff class 4.52 4.29 4.29 4.34 4.34 3.98 3.98 3.90 3.90 3.80 3.80
    Bedingung B (2 °C TK/1 °C FK) Pdh kW 2.40 3.90 3.90 3.90 3.90 6.03 6.03 7.71 7.71 8.62 8.62
      PERd % 176 170 170 170 170 162 162 163 163 150 150
      Space heating-=-Average climate water outlet 35°C-=-B Condition (2°CDB/1°CWB)-=-Copd 1.00 0.990 0.990 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (bivalente Temperatur) Pdh kW 4.36 4.93 4.93 7.14 7.14 9.09 9.09 11.6 11.6 12.1 12.1
      PERd % 104 98.8 98.8 98.8 98.8 113 113 113 113 102 102
      Tbiv °C -10.0 -8.00 -8.00 -8.00 -8.00 -5.00 -5.00 -5.00 -5.00 -4.00 -4.00
      Space heating-=-Average climate water outlet 35°C-=-Tbiv (bivalent temperature)-=-Copd 2.61 2.47 2.47 2.47 2.47 2.82 2.82 2.83 2.83 2.56 2.56
    Tol (Temperaturbetriebsgrenze) PERd % 104 91.6 91.6 91.6 91.6 93.6 93.6 104 104 82.0 82.0
      WTOL °C 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0 35.0
      Pdh kW 4.36 4.70 4.70 6.81 6.81 8.76 8.76 12.6 12.6 11.7 11.7
      TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      Space heating-=-Average climate water outlet 35°C-=-Tol (temperature operating limit)-=-Copd 2.61 2.29 2.29 2.29 2.29 2.34 2.34 2.60 2.60 2.05 2.05
  Warmes Klima Wasserauslass 55 °C Allgemein Jährlicher Energieverbrauch (GCV) Gj 4.20 5.37 5.37 6.85 6.85 9.47 9.47 11.8 11.8 12.3 12.3
      Prated bei 2°C kW 4.27 5.30 5.30 6.59 6.59 7.58 7.58 9.84 9.84 10.3 10.3
      Ƞs (Saisonale Effizienz Raumheizen) % 186 182 182 178 178 125 125 135 135 136 136
      Jährlicher Energieverbrauch kWh 1,168 1,491 1,491 1,904 1,904 2,630 2,630 3,270 3,270 3,420 3,420
  Wasserauslass kaltes Klima 35°C Allgemein Jährlicher Energieverbrauch Qhe (Brennwert) Gj           23.1 23.1 29.4 29.4 32.6 32.6
      Jährlicher Energieverbrauch kWh           6,430 6,430 8,170 8,170 9,050 9,050
      Ƞs (Saisonale Effizienz Raumheizen) %           148 148 141 141 137 137
      Prated bei -22°C kW           10.3 10.3 12.3 12.3 13.3 13.3
  Wasserauslass warmes Klima 35°C Allgemein Prated bei 2°C kW           9.06 9.06 10.9 10.9 11.4 11.4
      Ƞs (Saisonale Effizienz Raumheizen) %           192 192 199 199 199 199
      Jährlicher Energieverbrauch kWh           1,950 1,950 2,350 2,350 2,480 2,480
      Jährlicher Energieverbrauch (GCV) Gj           7.02 7.02 8.46 8.46 8.92 8.92
  Wasserauslass 55 °C für durchschnittliches Klima Bedingung A (-7 °C TK/-8 °C FK) PERd % 81.2 80.8 80.8 79.2 79.2 79.6 79.6 70.4 70.4 71.2 71.2
      Pdh kW 3.36 4.50 4.50 5.47 5.47 8.83 8.83 9.97 9.97 12.2 12.2
      Space heating-=-Average climate water outlet 55°C-=-A Condition (-7°CDB/-8°CWB)-=-Copd 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
    Tbiv (bivalente Temperatur) Tbiv °C -10.0 -9.00 -9.00 -10.0 -10.0 -7.00 -7.00 -6.00 -6.00 -7.00 -7.00
      Pdh kW 3.76 5.09 5.09 6.18 6.18 8.83 8.83 11.0 11.0 12.2 12.2
      PERd % 72.0 69.6 69.6 66.4 66.4 79.6 79.6 76.8 76.8 71.2 71.2
      Space heating-=-Average climate water outlet 55°C-=-Tbiv (bivalent temperature)-=-Copd 1.80 1.74 1.74 1.66 1.66 1.99 1.99 1.92 1.92 1.78 1.78
    Tol (Temperatur-Betriebsgrenze) TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      Pdh kW 3.76 4.62 4.62 6.18 6.18 9.08 9.08 12.2 12.2 13.3 13.3
      PERd % 72.0 69.6 69.6 66.4 66.4 71.6 71.6 70.0 70.0 68.4 68.4
      WTOL °C 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0 55.0
      Space heating-=-Average climate water outlet 55°C-=-Tol (temperature operating limit)-=-Copd 1.80 1.74 1.74 1.66 1.66 1.79 1.79 1.75 1.75 1.71 1.71
    Allgemein Jährlicher Energieverbrauch (GCV) Gj 8.48 12.1 12.1 14.6 14.6 22.6 22.6 28.4 28.4 32.3 32.3
      Saisonale Effizienz Raumheizen % 125 126 126 126 126 120 120 123 123 119 119
      Jährlicher Energieverbrauch kWh 2,356 3,369 3,369 4,064 4,064 6,260 6,260 7,900 7,900 8,970 8,970
      Prated bei -10 °C kW 3.70 5.30 5.30 6.40 6.40 9.99 9.99 12.7 12.7 13.9 13.9
      Space heating-=-Average climate water outlet 55°C-=-General-=-Seasonal space heating eff class 3.20 3.22 3.22 3.23 3.23 3.09 3.09 3.16 3.16 3.06 3.06
    Bedingung B (2 °C TK/1 °C FK) Pdh kW 2.00 4.43 4.43 3.43 3.43 5.28 5.28 6.76 6.76 7.61 7.61
      PERd % 123 127 127 127 127 130 130 142 142 125 125
      Space heating-=-Average climate water outlet 55°C-=-B Condition (2°CDB/1°CWB)-=-Copd 1.00 0.990 0.990 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
    Bedingung C (7 °C TK/6 °C FK) Pdh kW 2.77 3.51 3.51 3.50 3.50 4.47 4.47 4.66 4.66 4.83 4.83
      PERd % 171 168 168 168 168 172 172 169 169 176 176
      Space heating-=-Average climate water outlet 55°C-=-C Condition (7°CDB/6°CWB)-=-Copd 0.990 0.990 0.990 0.990 0.990 0.950 0.950 0.950 0.950 1.00 1.00
    Bedingung D (12 °C TK/11 °C FK) PERd % 253 233 233 233 233 256 256 218 218 254 254
      Pdh kW 2.65 3.28 3.28 3.28 3.28 5.37 5.37 5.26 5.26 5.38 5.38
      Space heating-=-Average climate water outlet 55°C-=-D Condition (12°CDB/11°CWB)-=-Copd 0.990 0.990 0.990 0.990 0.990 0.930 0.930 0.940 0.940 0.930 0.930
    Nenn-Heizleistung Zusatzheizung Psup (bei Tdesign -10 °C) kW 0.00 0.680 0.680 0.220 0.220 0.910 0.910 0.550 0.550 0.580 0.580
Heizleistung Nom. kW 4.40 (1), 4.03 (2) 6.00 (1), 5.67 (2) 6.00 (1), 5.67 (2) 7.40 (1), 6.89 (2) 7.40 (1), 6.89 (2) 11.2 (1), 11.0 (2) 11.2 (1), 11.0 (2) 14.5 (1), 13.6 (2) 14.5 (1), 13.6 (2) 16.0 (1), 15.2 (2) 16.0 (1), 15.2 (2)
  Min. kW 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1)            
  Max. kW 5.12 (1), 4.90 (2) 8.35 (1), 7.95 (2) 8.35 (1), 7.95 (2) 10.0 (1), 9.53 (2) 10.0 (1), 9.53 (2) 8.60 (3), 8.60 (4) 8.60 (3), 8.60 (4) 10.6 (3), 10.8 (4) 10.6 (3), 10.8 (4) 11.4 (3), 10.9 (4) 11.4 (3), 10.9 (4)
Allgemein LW(A) Schallleistungspegel (entsprechend EN14825) Innen dB(A) 42.0 42.0 42.0 42.0 42.0 42.0 42.0 44.0 44.0 44.0 44.0
  Lieferanten-/Herstellerdetails Name und Adresse Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Produktbeschreibung General-=-Product description-=-Low temperature heat pump Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
LW(A) Schallleistungspegel (gemäß EN14825) Außen dB(A) 61.0 62.0 62.0 62.0 62.0 64.0 64.0 64.0 64.0 66.0 66.0
Leistungsaufnahme Heizen Max. kW           3.13 (3), 4.10 (4) 3.13 (3), 4.10 (4) 4.00 (3), 5.19 (4) 4.00 (3), 5.19 (4) 4.32 (3), 5.22 (4) 4.32 (3), 5.22 (4)
    Nom. kW 0.870 (1), 1.13 (2) 1.27 (1), 1.59 (2) 1.27 (1), 1.59 (2) 1.66 (1), 2.01 (2) 1.66 (1), 2.01 (2) 2.43 (1), 3.10 (2) 2.43 (1), 3.10 (2) 3.37 (1), 4.10 (2) 3.37 (1), 4.10 (2) 3.76 (1), 4.66 (2) 3.76 (1), 4.66 (2)
Sound condition ecodesign and energy label 5.04 (1), 3.58 (2) 4.74 (1), 3.56 (2) 4.74 (1), 3.56 (2) 4.45 (1), 3.42 (2) 4.45 (1), 3.42 (2) 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4)
Hinweise Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C)
  Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C)
  T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C
  Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C
  TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C)
  TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C)
  Enthält fluorierte Treibhausgase Enthält fluorierte Treibhausgase Enthält fluorierte Treibhausgase Enthält fluorierte Treibhausgase Enthält fluorierte Treibhausgase TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C)
            TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C)