EHVH04S18CB3V / ERLQ004CAV3 EHVH08S26CB9W / ERLQ006CAV3 EHVH08S18CB3V / ERLQ006CAV3 EHVH08S18CB3V / ERLQ008CAV3 EHVH08S26CB9W / ERLQ008CAV3 EHVH11S18CB3V / ERLQ011CAV3 EHVH11S26CB9W / ERLQ011CAV3 EHVH16S26CB9W / ERLQ014CAV3 EHVH16S18CB3V / ERLQ014CAV3 EHVH16S26CB9W / ERLQ016CAV3 EHVH16S18CB3V / ERLQ016CAV3
Heizleistung Min. kW 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1)            
  Nom. kW 4.40 (1), 4.03 (2) 6.00 (1), 5.67 (2) 6.00 (1), 5.67 (2) 7.40 (1), 6.89 (2) 7.40 (1), 6.89 (2) 11.2 (1), 11.0 (2) 11.2 (1), 11.0 (2) 14.5 (1), 13.6 (2) 14.5 (1), 13.6 (2) 16.0 (1), 15.2 (2) 16.0 (1), 15.2 (2)
  Max. kW 5.12 (1), 4.90 (2) 8.35 (1), 7.95 (2) 8.35 (1), 7.95 (2) 10.0 (1), 9.53 (2) 10.0 (1), 9.53 (2) 8.60 (3), 8.60 (4) 8.60 (3), 8.60 (4) 10.6 (3), 10.8 (4) 10.6 (3), 10.8 (4) 11.4 (3), 10.9 (4) 11.4 (3), 10.9 (4)
Leistungsaufnahme Heizen Nom. kW 0.870 (1), 1.13 (2) 1.27 (1), 1.59 (2) 1.27 (1), 1.59 (2) 1.66 (1), 2.01 (2) 1.66 (1), 2.01 (2) 2.43 (1), 3.10 (2) 2.43 (1), 3.10 (2) 3.37 (1), 4.10 (2) 3.37 (1), 4.10 (2) 3.76 (1), 4.66 (2) 3.76 (1), 4.66 (2)
    Max. kW           3.13 (3), 4.10 (4) 3.13 (3), 4.10 (4) 4.00 (3), 5.19 (4) 4.00 (3), 5.19 (4) 4.32 (3), 5.22 (4) 4.32 (3), 5.22 (4)
COP 5.04 (1), 3.58 (2) 4.74 (1), 3.56 (2) 4.74 (1), 3.56 (2) 4.45 (1), 3.42 (2) 4.45 (1), 3.42 (2) 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4)
Pumpe Gerät mit nominalem externen statischen Druck Heizen kPa 53.0 (5), 56.0 (6) 45.0 (5), 47.0 (6) 45.0 (5), 47.0 (6) 33.0 (5), 37.0 (6) 33.0 (5), 37.0 (6) 34.2 (7), 35.9 (8) 34.2 (7), 35.9 (8) 43.2 (7), 51.2 (8) 43.2 (7), 51.2 (8) 26.8 (7), 36.3 (8) 26.8 (7), 36.3 (8)
Wasserseitiger Wärmetauscher Wasserdurchfluss Heizen Nom. l/min 12.6 (5), 11.6 (6) 17.2 (5), 16.3 (6) 17.2 (5), 16.3 (6) 21.2 (5), 19.8 (6) 21.2 (5), 19.8 (6) 32.1 (7), 31.5 (8) 32.1 (7), 31.5 (8) 41.6 (7), 39.0 (8) 41.6 (7), 39.0 (8) 45.9 (7), 43.6 (8) 45.9 (7), 43.6 (8)
Allgemein Lieferanten-/Herstellerdetails Name und Adresse   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Name oder Marke   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Produktbeschreibung Luft-Wasser-Wärmepumpe   Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
    Sole-Wasser-Wärmepumpe   Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein
    Wärmepumpenkombination Heizen   Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
    Niedertemperatur-Wärmepumpe   Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein
    Integrierter Zusatzheizer   Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
    Wasser-Wasser-Wärmepumpe   Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein Nein
  LW(A) Schallleistungspegel (entsprechend EN14825) Innen dB(A) 42.0 42.0 42.0 42.0 42.0 42.0 42.0 44.0 44.0 44.0 44.0
LW(A) Schallleistungspegel (gemäß EN14825) Außen dB(A) 61.0 62.0 62.0 62.0 62.0 64.0 64.0 64.0 64.0 66.0 66.0
Schallbedingungen Ökodesign-Richtlinie und Energieeffizienzklasse Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825
Tank Name   Warmwasserspeicher aus Edelstahl 180 l         Warmwasserspeicher aus Edelstahl 180 l Warmwasserspeicher aus Edelstahl 260 l Warmwasserspeicher aus Edelstahl 260 l Warmwasserspeicher aus Edelstahl 180 l Warmwasserspeicher aus Edelstahl 260 l Warmwasserspeicher aus Edelstahl 180 l
Raumheizen allgemein Luft-zu-Wasser-Gerät Nenn-Luftstrom (außen) m³/h 2,700 2,820 2,820 2,820 2,820 5,400 5,400 5,400 5,400 5,400 5,400
  Sole/Wasser-zu-Wasser-Gerät Nenndurchfluss Wasser/Sole m³/h     0.00 0.00 0.00            
  Sonstiges Leistungsregelung   Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter
    Cdh (Verschlechterung Heizung)   1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
    Pck (Kurbelwannenheizbetrieb) kW 0.00 0.00 0.00 0.00 0.00 0.055 0.055 0.055 0.055 0.055 0.055
    Poff (Modus AUS) kW 0.0080 0.0080 0.0080 0.0080 0.0080 0.055 0.055 0.055 0.055 0.055 0.055
    Psb (Standby-Modus) kW 0.0080 0.0080 0.0080 0.0080 0.0080 0.055 0.055 0.055 0.055 0.055 0.055
    Pto (Thermostat AUS) kW 0.0060 0.0070 0.0070 0.0080 0.0080 0.057 0.057 0.057 0.057 0.057 0.057
  Integrierter Zusatzheizer NOx-Emission mg/kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Psup kW 3.00 3.00 3.00 3.00 9.00 3.00 9.00 9.00 3.00 9.00 3.00
    Art der Energieaufnahme   Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch
Trinkwassererwärmung Allgemein Deklariertes Lastprofil   L XL L L XL L XL XL L XL L
    Funktion für feste Wasseraufheizung während Spitzenstunden   Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja Ja
  Durchschnittliches Klima AEC (Jährlicher Stromverbrauch) kWh 1,080 1,870 1,190 1,190 1,870 1,170 1,720 1,720 1,170 1,720 1,170
    AFC (Jährlicher Brennstoffverbrauch) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Ƞwh (Wasserheizeffizienz) % 95.0 90.0 86.4 86.4 90.0 87.4 97.7 97.7 87.4 97.7 87.4
    Qelec (Täglicher Stromverbrauch) kWh 4.93 8.50 5.43 5.43 8.50 5.32 7.83 7.83 5.32 7.83 5.32
    Qfuel (Täglicher Brennstoffverbrauch) kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Energieeffizienzklasse Wasserheizung   A A A A A A A A A A A
  Kaltes Klima AEC (Jährlicher Stromverbrauch) kWh 1,220 2,040 1,330 1,330 2,040 1,340 1,980 1,980 1,340 1,980 1,340
    AFC (Jährlicher Brennstoffverbrauch) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Ƞwh (Wasserheizeffizienz) % 84.0 83.0 77.5 77.5 83.0 76.6 85.1 85.1 76.6 85.1 76.6
    Qelec (Täglicher Stromverbrauch) kWh 5.55 9.26 6.05 6.05 9.26 6.08 8.99 8.99 6.08 8.99 6.08
    Qfuel (Täglicher Brennstoffverbrauch) kWh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Warmes Klima AEC (Jährlicher Stromverbrauch) kWh 966 1,780 1,120 1,120 1,780 1,110 1,630 1,630 1,110 1,630 1,110
    AFC (Jährlicher Brennstoffverbrauch) Gj 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
    Ƞwh (Wasserheizeffizienz) % 106 94.0 91.8 91.8 94.0 92.3 103 103 92.3 103 92.3
    Qelec (Täglicher Stromverbrauch) kWh 4.39 8.11 5.10 5.10 8.11 5.04 7.40 7.40 5.04 7.40 5.04
    Qfuel (Täglicher Brennstoffverbrauch) kWh           0.00 0.00 0.00 0.00 0.00 0.00
Raumheizen Wasserauslass 55 °C für durchschnittliches Klima Allgemein Jährlicher Energieverbrauch kWh 2,360   3,370         7,900 7,900 8,970 8,970
      Saisonale Effizienz Raumheizen % 125   126         123 123 119 119
      Prated bei -10 °C kW 3.70   5.30         12.7 12.7 13.9 13.9
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj 8.48   12.1         28.4 28.4 32.3 32.3
      SCOP   3.20   3.22         3.16 3.16 3.06 3.06
      Saisonale Effizienzklasse Raumheizen   A++   A++         A+ A+ A+ A+
    Bedingung A (-7 °C TK/-8 °C FK) Cdh (Verschlechterung Heizung)   1.00   1.00         1.00 1.00 1.00 1.00
      COPd   2.03   2.02         1.76 1.76 1.78 1.78
      Pdh kW 3.36   4.56         9.97 9.97 12.2 12.2
      PERd % 81.2   80.8         70.4 70.4 71.2 71.2
    Bedingung B (2 °C TK/1 °C FK) Cdh (Verschlechterung Heizung)   1.00   0.990         1.00 1.00 1.00 1.00
      COPd   3.08   3.17         3.55 3.55 3.12 3.12
      Pdh kW 2.00   3.43         6.76 6.76 7.61 7.61
      PERd % 123   127         142 142 125 125
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   0.990   0.990         0.950 0.950 1.00 1.00
      COPd   4.27   4.20         4.22 4.22 4.40 4.40
      Pdh kW 2.77   3.51         4.66 4.66 4.83 4.83
      PERd % 171   168         169 169 176 176
    Bedingung D (12 °C TK/11 °C FK) Cdh (Verschlechterung Heizung)   0.990   0.990         0.940 0.940 0.930 0.930
      COPd   6.33   5.82         5.44 5.44 6.36 6.36
      Pdh kW 2.65   3.28         5.26 5.26 5.38 5.38
      PERd % 253   233         218 218 254 254
    Tol (Temperatur-Betriebsgrenze) COPd   1.80   1.74         1.75 1.75 1.71 1.71
      Pdh kW 3.76   3.10         12.2 12.2 13.3 13.3
      PERd % 72.0   69.6         70.0 70.0 68.4 68.4
      TOL °C -10.0   -10.0         -10.0 -10.0 -10.0 -10.0
      WTOL °C 55.0   55.0         55.0 55.0 55.0 55.0
    Nenn-Heizleistung Zusatzheizung Psup (bei Tdesign -10 °C) kW 0.00   2.20         0.550 0.550 0.580 0.580
    Tbiv (bivalente Temperatur) COPd   1.80   1.87         1.92 1.92 1.78 1.78
      Pdh kW 3.76   4.90         11.0 11.0 12.2 12.2
      PERd % 72.0   74.8         76.8 76.8 71.2 71.2
      Tbiv °C -10.0   -8.00         -6.00 -6.00 -7.00 -7.00
  Wasserauslass kaltes Klima 55 °C Allgemein Jährlicher Energieverbrauch kWh 2,130   2,310         7,870 7,870 8,580 8,580
      Saisonale Effizienz Raumheizen % 107   107         95.5 95.5 98.3 98.3
      Prated bei -22°C kW 2.39   2.60         8.15 8.15 9.12 9.12
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj 7.68   8.30         28.3 28.3 30.9 30.9
  Warmes Klima Wasserauslass 55 °C Allgemein Jährlicher Energieverbrauch kWh 1,170   1,490         3,270 3,270 3,420 3,420
      Ƞs (Saisonale Effizienz Raumheizen) % 186   182         135 135 136 136
      Prated bei 2°C kW 4.27   5.30         9.84 9.84 10.3 10.3
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj 4.20   5.37         11.8 11.8 12.3 12.3
  Wasserauslass 35°C für durchschnittliches Klima Allgemein SCOP   4.52   4.29         3.90 3.90 3.80 3.80
      Jährlicher Energieverbrauch kWh 1,980   2,540         7,250 7,250 8,270 8,270
      Ƞs (Saisonale Effizienz Raumheizen) % 178   169         153 153 149 149
      Prated bei -10 °C kW 4.40   5.34         14.5 14.5 16.0 16.0
      Jährlicher Energieverbrauch (GCV) Gj 7.13   9.14         26.1 26.1 29.8 29.8
      Saisonale Effizienzklasse Raumheizen   A++   A++         A++ A++ A+ A+
    Bedingung A (-7 °C TK/-8 °C FK) COPd   3.01   2.69         2.63 2.63 2.33 2.33
      Pdh kW 4.01   4.72         10.7 10.7 12.4 12.4
      PERd % 120   108         105 105 93.2 93.2
    Bedingung B (2 °C TK/1 °C FK) Cdh (Verschlechterung Heizung)   1.00   0.990         1.00 1.00 1.00 1.00
      COPd   4.41   4.24         4.07 4.07 3.74 3.74
      Pdh kW 2.40   3.90         7.71 7.71 8.62 8.62
      PERd % 176   170         163 163 150 150
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   0.980   0.980         1.00 1.00 0.940 0.940
      COPd   5.85   5.75         5.71 5.71 6.77 6.77
      Pdh kW 1.70   2.59         5.05 5.05 5.74 5.74
      PERd % 234   230         228 228 271 271
    Bedingung D (12 °C TK/11 °C FK) Cdh (Absinken Heizen)   0.980   0.980         0.930 0.930 0.920 0.920
      COPd   7.71   7.27         6.71 6.71 8.97 8.97
      Pdh kW 2.04   2.61         5.16 5.16 6.50 6.50
      PERd % 308   291         268 268 359 359
    Tol (Temperaturbetriebsgrenze) COPd   2.61   2.29         2.60 2.60 2.05 2.05
      Pdh kW 4.36   4.70         12.6 12.6 11.7 11.7
      PERd % 104   91.6         104 104 82.0 82.0
      TOL °C -10.0   -10.0         -10.0 -10.0 -10.0 -10.0
      WTOL °C 35.0   35.0         35.0 35.0 35.0 35.0
    Bedingung G (-15 °C TK/–) COPd   0.00   0.00                
      Pdh kW 0.00   0.00                
      PERd % 0.00   0.00                
    Tbiv (bivalente Temperatur) COPd   2.61   2.47         2.83 2.83 2.56 2.56
      Pdh kW 4.36   4.93         11.6 11.6 12.1 12.1
      PERd % 104   98.8         113 113 102 102
      Tbiv °C -10.0   -8.00         -5.00 -5.00 -4.00 -4.00
    Nennleistung Wärmeabgabe Zusatzheizer Psup (bei Tdesign -10 °C) kW 0.040   0.640         1.93 1.93 4.35 4.35
  Wasserauslass kaltes Klima 35°C Allgemein Jährlicher Energieverbrauch kWh               8,170 8,170 9,050 9,050
      Ƞs (Saisonale Effizienz Raumheizen) %               141 141 137 137
      Prated bei -22°C kW               12.3 12.3 13.3 13.3
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj               29.4 29.4 32.6 32.6
  Wasserauslass warmes Klima 35°C Allgemein Jährlicher Energieverbrauch kWh               2,350 2,350 2,480 2,480
      Ƞs (Saisonale Effizienz Raumheizen) %               199 199 199 199
      Prated bei 2°C kW               10.9 10.9 11.4 11.4
      Jährlicher Energieverbrauch (GCV) Gj               8.46 8.46 8.92 8.92
Hinweise (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C)
  (3) - T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) (3) - T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C (3) - Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C (3) - Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C (3) - Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C (3) - Bedingung 3: Heizen: Ta DB -7°C (RH 85 %) - LWC 35°C
  (4) - Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) (4) - Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C (4) - Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C (4) - Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C (4) - Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C (4) - Bedingung 4: Heizen: Ta DB -7°C (RH 85 %) - LWC 45°C
  (5) - TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) (5) - TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) T Umgebung 35°C – LWE 7°C (DT=5°C) (5) - T Umgebung 35°C – LWE 7°C (DT=5°C) (5) - T Umgebung 35°C – LWE 7°C (DT=5°C) (5) - T Umgebung 35°C – LWE 7°C (DT=5°C) (5) - T Umgebung 35°C – LWE 7°C (DT=5°C)
  (6) - TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) (6) - TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) Tamb 35 °C – LWE 18 °C (DT = 5 °C) (6) - Tamb 35 °C – LWE 18 °C (DT = 5 °C) (6) - Tamb 35 °C – LWE 18 °C (DT = 5 °C) (6) - Tamb 35 °C – LWE 18 °C (DT = 5 °C) (6) - Tamb 35 °C – LWE 18 °C (DT = 5 °C)
Raumheizen Wasserauslass 55 °C für durchschnittliches Klima Allgemein SCOP     3.22   3.20 3.20 3.09 3.09        
      Jährlicher Energieverbrauch kWh   3,370   4,100 4,100 6,260 6,260        
      Saisonale Effizienz Raumheizen %   126   125 125 120 120        
      Prated bei -10 °C kW   5.30   6.40 6.40 9.99 9.99        
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj   12.1   14.8 14.8 22.6 22.6        
      Saisonale Effizienzklasse Raumheizen     A++   A++ A++ A+ A+        
    Bedingung A (-7 °C TK/-8 °C FK) Cdh (Verschlechterung Heizung)     1.00   1.00 1.00 1.00 1.00        
      COPd     2.02   1.98 1.98 1.99 1.99        
      Pdh kW   4.56   5.50 5.50 8.83 8.83        
      PERd %   80.8   79.2 79.2 79.6 79.6        
    Bedingung B (2 °C TK/1 °C FK) Cdh (Verschlechterung Heizung)     0.990   1.00 1.00 1.00 1.00        
      COPd     3.17   3.17 3.17 3.24 3.24        
      Pdh kW   3.43   3.43 3.43 5.28 5.28        
      PERd %   127   127 127 130 130        
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)     0.990   0.990 0.990 0.950 0.950        
      COPd     4.20   4.20 4.20 4.31 4.31        
      Pdh kW   3.51   3.50 3.50 4.47 4.47        
      PERd %   168   168 168 172 172        
    Bedingung D (12 °C TK/11 °C FK) Cdh (Verschlechterung Heizung)     0.990   0.990 0.990 0.930 0.930        
      COPd     5.82   5.82 5.82 6.41 6.41        
      Pdh kW   3.28   3.28 3.28 5.37 5.37        
      PERd %   233   233 233 256 256        
    Tol (Temperatur-Betriebsgrenze) COPd     1.74   1.74 1.74 1.79 1.79        
      Pdh kW   3.10   3.10 3.10 9.08 9.08        
      PERd %   69.6   69.6 69.6 71.6 71.6        
      TOL °C   -10.0   -10.0 -10.0 -10.0 -10.0        
      WTOL °C   55.0   55.0 55.0 55.0 55.0        
    Nenn-Heizleistung Zusatzheizung Psup (bei Tdesign -10 °C) kW   2.20   3.30 3.30 0.910 0.910        
    Tbiv (bivalente Temperatur) COPd     1.87   1.98 1.98 1.99 1.99        
      Pdh kW   4.90   5.50 5.50 8.83 8.83        
      PERd %   74.8   79.2 79.2 79.6 79.6        
      Tbiv °C   -8.00   -7.00 -7.00 -7.00 -7.00        
  Wasserauslass kaltes Klima 55 °C Allgemein Jährlicher Energieverbrauch kWh   2,310   3,090 3,090 6,740 6,740        
      Saisonale Effizienz Raumheizen %   107   110 110 95.0 95.0        
      Prated bei -22°C kW   2.60   3.56 3.56 6.99 6.99        
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj   8.30   11.1 11.1 24.3 24.3        
  Warmes Klima Wasserauslass 55 °C Allgemein Jährlicher Energieverbrauch kWh   1,490   1,840 1,840 2,630 2,630        
      Ƞs (Saisonale Effizienz Raumheizen) %   182   178 178 125 125        
      Prated bei 2°C kW   5.30   6.36 6.36 7.58 7.58        
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj   5.37   6.62 6.62 9.47 9.47        
  Wasserauslass 35°C für durchschnittliches Klima Allgemein SCOP     4.29   4.34 4.34 3.98 3.98        
      Jährlicher Energieverbrauch kWh   2,540   3,490 3,490 5,380 5,380        
      Ƞs (Saisonale Effizienz Raumheizen) %   169   171 171 156 156        
      Prated bei -10 °C kW   5.34   7.40 7.40 11.2 11.2        
      Jährlicher Energieverbrauch (GCV) Gj   9.14   12.6 12.6 19.4 19.4        
      Saisonale Effizienzklasse Raumheizen     A++   A++ A++ A++ A++        
    Bedingung A (-7 °C TK/-8 °C FK) COPd     2.69   2.69 2.69 2.63 2.63        
      Pdh kW   4.72   6.68 6.68 8.88 8.88        
      PERd %   108   108 108 105 105        
    Bedingung B (2 °C TK/1 °C FK) Cdh (Verschlechterung Heizung)     0.990   1.00 1.00 1.00 1.00        
      COPd     4.24   4.24 4.24 4.05 4.05        
      Pdh kW   3.90   3.90 3.90 6.03 6.03        
      PERd %   170   170 170 162 162        
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)     0.980   1.00 1.00 0.940 0.940        
      COPd     5.75   5.75 5.75 6.77 6.77        
      Pdh kW   2.59   2.59 2.59 5.74 5.74        
      PERd %   230   230 230 271 271        
    Bedingung D (12 °C TK/11 °C FK) Cdh (Absinken Heizen)     0.980   0.980 0.980 0.920 0.920        
      COPd     7.27   7.27 7.27 8.97 8.97        
      Pdh kW   2.61   2.61 2.61 6.50 6.50        
      PERd %   291   291 291 359 359        
    Tol (Temperaturbetriebsgrenze) COPd     2.29   2.29 2.29 2.34 2.34        
      Pdh kW   4.70   6.81 6.81 8.76 8.76        
      PERd %   91.6   91.6 91.6 93.6 93.6        
      TOL °C   -10.0   -10.0 -10.0 -10.0 -10.0        
      WTOL °C   35.0   35.0 35.0 35.0 35.0        
    Bedingung G (-15 °C TK/–) COPd     0.00   0.00 0.00            
      Pdh kW   0.00   0.00 0.00            
      PERd %   0.00   0.00 0.00            
    Tbiv (bivalente Temperatur) COPd     2.47   2.47 2.47 2.82 2.82        
      Pdh kW   4.93   7.14 7.14 9.09 9.09        
      PERd %   98.8   98.8 98.8 113 113        
      Tbiv °C   -8.00   -8.00 -8.00 -5.00 -5.00        
    Nennleistung Wärmeabgabe Zusatzheizer Psup (bei Tdesign -10 °C) kW   0.640   0.590 0.590 2.44 2.44        
  Wasserauslass kaltes Klima 35°C Allgemein Jährlicher Energieverbrauch kWh           6,430 6,430        
      Ƞs (Saisonale Effizienz Raumheizen) %           148 148        
      Prated bei -22°C kW           10.3 10.3        
      Jährlicher Energieverbrauch Qhe (Brennwert) Gj           23.1 23.1        
  Wasserauslass warmes Klima 35°C Allgemein Jährlicher Energieverbrauch kWh           1,950 1,950        
      Ƞs (Saisonale Effizienz Raumheizen) %           192 192        
      Prated bei 2°C kW           9.06 9.06        
      Jährlicher Energieverbrauch (GCV) Gj           7.02 7.02        
Hinweise           TK/FK 7°C/6°C-LWC 35°C(DT=5°C) TK/FK 7°C/6°C-LWC 35°C(DT=5°C) (7) - TK/FK 7°C/6°C-LWC 35°C(DT=5°C) (7) - TK/FK 7°C/6°C-LWC 35°C(DT=5°C) (7) - TK/FK 7°C/6°C-LWC 35°C(DT=5°C) (7) - TK/FK 7°C/6°C-LWC 35°C(DT=5°C)
            TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) (8) - TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) (8) - TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) (8) - TK/FK 7°C/6°C - LWC 45°C(Dt=5°C) (8) - TK/FK 7°C/6°C - LWC 45°C(Dt=5°C)