EHSXB04P50DA / ERGA04DAV3A EHSXB04P30DA / ERGA04DAV3A EHSXB08P30DA / ERGA06DAV3A EHSXB08P50DA / ERGA06DAV3A EHSXB08P50DA / ERGA08DAV3A EHSXB08P30DA / ERGA08DAV3A
Innengerät EHSXB04P50D EHSXB04P30D EHSXB08P30D EHSXB08P50D EHSXB08P50D EHSXB08P30D
Außengerät ERGA04DAV3A ERGA04DAV3A ERGA06DAV3A ERGA06DAV3A ERGA08DAV3A ERGA08DAV3A
Heizleistung Nom. kW 4.30 (1), 4.60 (2) 4.30 (1), 4.60 (2) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2)
Kühlleistung Nom. kW 5.56 (1), 4.37 (2) 5.56 (1), 4.37 (2) 5.96 (1), 4.87 (2) 5.96 (1), 4.87 (2) 6.25 (1), 5.35 (2) 6.25 (1), 5.35 (2)
Leistungsaufnahme Heizen Nom. kW 0.850 (1), 1.26 (2) 0.850 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2)
  Kühlung Nom. kW 0.940 (1), 1.14 (2) 0.940 (1), 1.14 (2) 1.06 (1), 1.33 (2) 1.06 (1), 1.33 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2)
Heat up time from 10°C to 50°C hr 2h38min 1h31min 1h31min 2h38min 2h38min 1h31min
COP 5.10 (1), 3.65 (2) 5.10 (1), 3.65 (2) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2)
EER 5.94 (1), 3.84 (2) 5.94 (1), 3.84 (2) 5.61 (1), 3.67 (2) 5.61 (1), 3.67 (2) 5.40 (1), 3.54 (2) 5.40 (1), 3.54 (2)
Pumpe Type   Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL        
  Gerät mit nominalem externen statischen Druck Kühlung kPa 60.5 (1), 65.8 (2) 60.5 (1), 65.8 (2) 57.6 (1), 63.9 (2) 57.6 (1), 63.9 (2) 55.5 (1), 61.7 (2) 55.5 (1), 61.7 (2)
    Heizen kPa 66.0 (1), 65.0 (2) 66.0 (1), 65.0 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 42.7 (1), 38.7 (2) 42.7 (1), 38.7 (2)
Wasserseitiger Wärmetauscher Wasserdurchfluss Kühlung Nom. l/min 15.9 (1), 12.5 (2) 15.9 (1), 12.5 (2) 17.1 (1), 14.0 (2) 17.1 (1), 14.0 (2) 17.9 (1), 15.3 (2) 17.9 (1), 15.3 (2)
    Heizen Nom. l/min 12.3 (1), 13.2 (2) 12.3 (1), 13.2 (2) 17.2 (1), 16.9 (2) 17.2 (1), 16.9 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2)
Allgemein Produktbeschreibung Luft-Wasser-Wärmepumpe   Ja Ja Ja Ja Ja Ja
    Sole-Wasser-Wärmepumpe   Nein Nein Nein Nein Nein Nein
    Wärmepumpenkombination Heizen   Ja Ja Ja Ja Ja Ja
    Niedertemperatur-Wärmepumpe   Nein Nein Nein Nein Nein Nein
    Integrierter Zusatzheizer   Nein Nein Nein Nein Nein Nein
    Wasser-Wasser-Wärmepumpe   Nein Nein Nein Nein Nein Nein
  LW(A) Schallleistungspegel (entsprechend EN14825) Innen dB(A) 39 39 39 39 39 39
LW(A) Schallleistungspegel (gemäß EN14825) Außen dB(A) 58 58 60 60 62 62
Schallbedingungen Ökodesign-Richtlinie und Energieeffizienzklasse Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825 Schallleistung im Heizbetrieb, gemessen gemäß EN12102 unter den Bedingungen von EN14825
Raumheizen allgemein Luft-zu-Wasser-Gerät Nenn-Luftstrom (außen) m³/h 2,280 2,280 27,770 27,770 2,770 2,770
  Sonstiges Leistungsregelung   Inverter Inverter Inverter Inverter Inverter Inverter
    Poff (Modus AUS) kW 0.010 0.010 0.010 0.010 0.010 0.010
    Psb (Standby-Modus) kW 0.010 0.010 0.010 0.010 0.010 0.010
    Pto (Thermostat AUS) kW 0.010 0.010 0.010 0.010 0.010 0.010
  Integrierter Zusatzheizer Art der Energieaufnahme   Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch Elektrisch
Trinkwassererwärmung Allgemein Deklariertes Lastprofil   XL L L XL XL L
    Funktion für feste Wasseraufheizung während Spitzenstunden   Ja Ja Ja Ja Ja Ja
  Durchschnittliches Klima AEC (Jährlicher Stromverbrauch) kWh 1,541 951 951 1,541 1,541 951
    Ƞwh (Wasserheizeffizienz) % 109 108 108 109 109 108
    Qelec (Täglicher Stromverbrauch) kWh 7.251 4.500 4.500 7.251 7.251 4.500
    Energieeffizienzklasse Wasserheizung   A A A A A A
  Kaltes Klima AEC (Jährlicher Stromverbrauch) kWh 1,852 1,366 1,366 1,852 1,852 1,366
    Ƞwh (Wasserheizeffizienz) % 90 75 75 90 90 75
    Qelec (Täglicher Stromverbrauch) kWh 8.665 6.454 6.454 8.665 8.665 6.454
  Warmes Klima AEC (Jährlicher Stromverbrauch) kWh 1,343 940 940 1,343 1,343 940
    Ƞwh (Wasserheizeffizienz) % 125 109 109 125 125 109
    Qelec (Täglicher Stromverbrauch) kWh 6.346 4.513 4.513 6.346 6.346 4.513
Raumheizen Wasserauslass 55 °C für durchschnittliches Klima Allgemein SCOP   3.26 3.26 3.25 3.25 3.27 3.27
      Jährlicher Energieverbrauch kWh 3,806 3,806 4,456 4,456 4,731 4,731
      Saisonale Effizienz Raumheizen % 127 127 127 127 128 128
      Prated bei -10 °C kW 6.0 6.0 7.0 7.0 7.5 7.5
      Saisonale Effizienzklasse Raumheizen   A++ A++ A++ A++ A++ A++
    Bedingung A (-7 °C TK/-8 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   1.97 1.97 1.98 1.98 198.00 198.00
      Pdh kW 5.3 5.3 5.9 5.9 5.9 5.9
      PERd % 79.0 79.0 79.0 79.0 79.0 79.0
    Bedingung B (2 °C TK/1 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.23 3.23 3.16 3.16 3.18 3.18
      Pdh kW 3.3 3.3 3.9 3.9 4.1 4.1
      PERd % 129.0 129.0 126.0 126.0 127.0 127.0
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.40 4.40 4.49 4.49 4.54 4.54
      Pdh kW 3.0 3.0 3.0 3.0 3.0 3.0
      PERd % 176.0 176.0 180.0 180.0 182.0 182.0
    Bedingung D (12 °C TK/11 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.16 6.16
      Pdh kW 3.3 3.3 3.3 3.3 3.7 3.7
      PERd % 244.0 244.0 244.0 244.0 246.0 246.0
    Tol (Temperatur-Betriebsgrenze) COPd   1.37 1.37 1.43 1.43 1.43 1.43
      Pdh kW 4.0 4.0 4.5 4.5 4.5 4.5
      PERd % 55.0 55.0 57.0 57.0 57.0 57.0
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55
    Tbiv (bivalente Temperatur) COPd   1.97 1.97 2.12 2.12 2.18 2.18
      Pdh kW 5.3 5.3 6.1 6.1 6.4 6.4
      PERd % 79.0 79.0 85.0 85.0 87.0 87.0
      Tbiv °C -7 -7 -6 -6 -6 -6
  Wasserauslass kaltes Klima 55 °C Allgemein Jährlicher Energieverbrauch kWh 4,468 4,468 5,325 5,325 7,066 7,066
      Saisonale Effizienz Raumheizen % 107 107 108 108 109 109
      Prated bei -22°C kW 5 5 6 6 8 8
  Warmes Klima Wasserauslass 55 °C Allgemein Jährlicher Energieverbrauch kWh 1,660 1,660 1,858 1,858 1,983 1,983
      Ƞs (Saisonale Effizienz Raumheizen) % 148 148 158 158 159 159
      Prated bei 2°C kW 5 5 6 6 6 6
  Wasserauslass 35°C für durchschnittliches Klima Allgemein SCOP   4.48 4.48 4.47 4.47 4.56 4.56
      Jährlicher Energieverbrauch kWh 2,766 2,766 3,233 3,233 3,625 3,625
      Ƞs (Saisonale Effizienz Raumheizen) % 176 176 176 176 179 179
      Prated bei -10 °C kW 6.0 6.0 7.0 7.0 8.0 8.0
      Jährlicher Energieverbrauch (GCV) Gj 1 1 1 1 1 1
      Saisonale Effizienzklasse Raumheizen   A++ A++ A++ A++ A++ A++
    Bedingung A (-7 °C TK/-8 °C FK) COPd   2.90 2.90 2.86 2.86 2.77 2.77
      Pdh kW 5.5 5.5 6.0 6.0 7.0 7.0
      PERd % 116.0 116.0 114.0 114.0 111.0 111.0
    Bedingung B (2 °C TK/1 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.33 4.33 4.25 4.25 4.35 4.35
      Pdh kW 3.3 3.3 3.9 3.9 4.2 4.2
      PERd % 173.0 173.0 170.0 170.0 174.0 174.0
    Bedingung C (7 °C TK/6 °C FK) Cdh (Verschlechterung Heizung)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.19 6.19 6.30 6.30 6.49 6.49
      Pdh kW 3.2 3.2 3.2 3.2 3.3 3.3
      PERd % 248.0 248.0 252.0 252.0 260.0 260.0
    Bedingung D (12 °C TK/11 °C FK) Cdh (Absinken Heizen)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.78 7.78 7.78 7.78 8.52 8.52
      Pdh kW 3.3 3.3 3.3 3.3 3.9 3.9
      PERd % 311.0 311.0 311.0 311.0 341.0 341.0
    Tol (Temperaturbetriebsgrenze) COPd   2.56 2.56 2.49 2.49 2.41 2.41
      Pdh kW 5.2 5.2 6.0 6.0 6.9 6.9
      PERd % 102.0 102.0 100.0 100.0 96.0 96.0
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35
    Tbiv (bivalente Temperatur) COPd   2.90 2.90 3.07 3.07 2.66 2.66
      Pdh kW 5.5 5.5 6.1 6.1 7.5 7.5
      PERd % 116.0 116.0 123.0 123.0 106.0 106.0
      Tbiv °C -7 -7 -6 -6 -8 -8
  Wasserauslass kaltes Klima 35°C Allgemein Jährlicher Energieverbrauch kWh 3,230 3,230 3,749 3,749 5,052 5,052
      Ƞs (Saisonale Effizienz Raumheizen) % 150 150 155 155 153 153
      Prated bei -22°C kW 5 5 6 6 8 8
  Wasserauslass warmes Klima 35°C Allgemein Jährlicher Energieverbrauch kWh 1,139 1,139 1,276 1,276   1,437
      Ƞs (Saisonale Effizienz Raumheizen) % 241 241 248 248   257
      Prated bei 2°C kW 5 5 6 6   7
Hinweise Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C) Bedingung 1: Kühlen: Ta 35°C - LWE 18°C (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 35°C (DT = 5°C)
  Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C) Bedingung 2: Kühlen: Ta 35°C - LWE 7℃ (DT = 5°C); Heizen: Ta TK/FK 7°C/6°C - LWC 45℃ (DT = 5°C)